1.William Harvey Cardiovascular Research Institute, Queen Mary University of London and Barts Heart Centre, London EC1A 7BE, UK
2.Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, Charles Bell House, 67-73 Riding House Street, London W1W 7EJ, UK
3.UCL Centre for Materials Research, Department of Chemistry, University College London, London WC1H 0AJ, UK
4.Department of Electronic and Electrical Engineering, University College London, London WC1E 7JE, UK
AE Desjardins, Email: a.desjardins@ucl.ac.uk
Published:2017-12,
Published Online:01 December 2017,
Received:04 January 2017,
Revised:11 June 2017,
Accepted:14 June 2017
Scan QR Code
Finlay, M. C. et al. Through-needle all-optical ultrasound imaging in vivo: a preclinical swine study. Light: Science & Applications, 6, e17103 (2017).
Finlay, M. C. et al. Through-needle all-optical ultrasound imaging in vivo: a preclinical swine study. Light: Science & Applications, 6, e17103 (2017). DOI: 10.1038/lsa.2017.103.
High-frequency ultrasound imaging can provide exquisite visualizations of tissue to guide minimally invasive procedures. Here
we demonstrate that an all-optical ultrasound transducer
through which light guided by optical fibers is used to generate and receive ultrasound
is suitable for real-time invasive medical imaging
in vivo
. Broad-bandwidth ultrasound generation was achieved through the photoacoustic excitation of a multiwalled carbon nanotube-polydimethylsiloxane composite coating on the distal end of a 300-μm multi-mode optical fiber by a pulsed laser. The interrogation of a high-finesse Fabry–Pérot cavity on a single-mode optical fiber by a wavelength-tunable continuous-wave laser was applied for ultrasound reception. This transducer was integrated within a custom inner transseptal needle (diameter 1.08 mm; length 78 cm) that included a metallic septum to acoustically isolate the two optical fibers. The use of this needle within the beating heart of a pig provided unprecedented real-time views (50 Hz scan rate) of cardiac tissue (depth: 2.5 cm; axial resolution: 64 μm) and revealed the critical anatomical structures required to safely perform a transseptal crossing: the right and left atrial walls
the right atrial appendage
and the limbus fossae ovalis. This new paradigm will allow ultrasound imaging to be integrated into a broad range of minimally invasive devices in different clinical contexts.
cardiacmedical devicesoptoacousticphotoacousticultrasound
Biagi E, Cerbai S, Masotti L, Belsito L, Roncaglia Aet al. Fiber optic broadband ultrasonic probe for virtual biopsy: technological solutions.J Sensors2010;2010: 917314..
Zou XT, Wu N, Tian Y, Wang XW. Broadband miniature fiber optic ultrasound generator.Opt Express2014;22: 18119–18127..
Sheaff C, Ashkenazi S. Polyimide-etalon all-optical ultrasound transducer for high frequency applications.Proc SPIE2014;8943: 89434M..
Colchester RJ, Zhang EZ, Mosse CA, Beard PC, Papakonstantinou Iet al. Broadband miniature optical ultrasound probe for high resolution vascular tissue imaging.Biomed Opt Express2015;6: 1502–1511..
Hsieh BY, Chen SL, Ling T, Guo LJ, Li PC. All-optical scanhead for ultrasound and photoacoustic imaging—Imaging mode switching by dichroic filtering.Photoacoustics2014;2: 39–46..
Alles EJ, Colchester RJ, Desjardins AE. Adaptive light modulation for improved resolution and efficiency in all-optical pulse-echo ultrasound.IEEE Trans Ultrason Ferroelectr Freq Control2016;63: 83–90..
Vannacci E, Granchi S, Belsito L, Roncaglia A, Biagi E. Wide bandwidth fiber-optic ultrasound probe in MOMS technology: preliminary signal processing results.Ultrasonics2016;75: 164–173..
Earley MJ. How to perform a transseptal puncture.Heart2009;95: 85–92..
Ross J Jr. Transseptal left heart catheterization: a 50-year odyssey.J Am Coll Cardiol2008;51: 2107–2115..
Babaliaros VC, Green JT, Lerakis S, Lloyd M, Block PC. Emerging applications for transseptal left heart catheterization: old techniques for new procedures.J Am Coll Cardiol2008;51: 2116–2122..
Baac HW, Ok JG, Park HJ, Ling T, Chen SLet al. Carbon nanotube composite optoacoustic transmitters for strong and high frequency ultrasound generation.App Phys Lett2010;97: 234104..
Baac HW, Ok JG, Lee T, Guo LJ. Nano-structural characteristics of carbon nanotube-polymer composite films for high-amplitude optoacoustic generation.Nanoscale2015;7: 14460–14468..
Colchester RJ, Mosse CA, Bhachu DS, Bear JC, Carmalt CJet al. Laser-generated ultrasound with optical fibres using functionalised carbon nanotube composite coatings.App Phys Lett2014;104: 173502..
Noimark S, Colchester RJ, Blackburn BJ, Zhang EZ, Alles EJet al. Carbon-nanotube-PDMS composite coatings on optical fibers for all-optical ultrasound imaging.Adv Funct Mater2016;26: 8390–8396..
Zhang EZ, Beard PC. Characteristics of optimized fibre-optic ultrasound receivers for minimally invasive photoacoustic detection.Proc SPIE2015;9323: 932311..
Morris P, Hurrell A, Shaw A, Zhang E, Beard P. A Fabry-Pérot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure.J Acoust Soc Am2009;125: 3611–3622..
Biagi E, Margheri F, Menichelli D. Efficient laser-ultrasound generation by using heavily absorbing films as targets.IEEE Trans Ultrason Ferroelectr Freq Control2001;48: 1669–1680..
van Soest G, Regar E, van der Steen AFW. Photonics in cardiovascular medicine.Nat Photonics2015;9: 626–629..
Taruttis A, Herzog E, Razansky D, Ntziachristos V. Real-time imaging of cardiovascular dynamics and circulating gold nanorods with multispectral optoacoustic tomography.Opt Express2010;18: 19592–19602..
Taruttis A, Wildgruber M, Kosanke K, Beziere N, Licha Ket al. Multispectral optoacoustic tomography of myocardial infarction.Photoacoustics2013;1: 3–8..
Pang GA, Bay E, Deán-Ben XL, Razansky D. Three-dimensional optoacoustic monitoring of lesion formation in real time during radiofrequency catheter ablation.J Cardiovasc Electrophysiol2015;26: 339–345..
Deán-Ben XL, Ford SJ, Razansky D. High-frame rate four dimensional optoacoustic tomography enables visualization of cardiovascular dynamics and mouse heart perfusion.Sci Rep2015;5: 10133..
Xia WF, Nikitichev DI, Mari JM, West SJ, Pratt Ret al. Performance characteristics of an interventional multispectral photoacoustic imaging system for guiding minimally invasive procedures.J Biomed Opt2015;20: 086005..
Piras D, Grijsen C, Schütte P, Steenbergen W, Manohar S. Photoacoustic needle: minimally invasive guidance to biopsy.J Biomed Opt2013;18: 070502..
Boppart SA, Tearney GJ, Bouma BE, Southern JF, Brezinski MEet al. Noninvasive assessment of the developing Xenopus cardiovascular system using optical coherence tomography.Proc Natl Acad Sci USA1997;94: 4256–4261..
Villiger M, Lorenser D, McLaughlin RA, Quirk BC, Kirk RWet al. Deep tissue volume imaging of birefringence through fibre-optic needle probes for the delineation of breast tumour.Sci Rep2016;6: 28771..
Li XD, Chudoba C, Ko T, Pitris C, Fujimoto JG. Imaging needle for optical coherence tomography.Opt Lett2000;25: 1520–1522..
Xia WF, Mari JM, West SJ, Ginsberg Y, David ALet al. In-plane ultrasonic needle tracking using a fiber-optic hydrophone.Med Phys2015;42: 5983–5991..
Wright M, Harks E, Deladi S, Suijver F, Barley Met al. Real-time lesion assessment using a novel combined ultrasound and radiofrequency ablation catheter.Heart Rhythm2011;8: 304–312..
Chiang HK, Zhou QF, Mandell MS, Tsou MY, Lin SPet al. Eyes in the Needle: novel epidural needle with embedded high-frequency ultrasound transducer—epidural access in porcine model.Anesthesiology2011;114: 1320–1324..
Lee PY, Huang CC, Chiang HK. Implementation of a novel high frequency ultrasound device for guiding epidural anesthesia-in vivo animal study. Proceedings of 2013 IEEE International Ultrasonics Symposium; 21-25 July 2013; Prague, Czech Republic. IEEE: Prague, Czech Republic; 2013.
Gurun G, Tekes C, Zahorian J, Xu T, Satir Set al. Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.IEEE Trans Ultrason Ferroelectr Freq Control2014;61: 239–250..
Ameri G, Son J, Liang JW, Foster FS, Ganapathy Set al. Development of a high frequency single-element ultrasound needle transducer for anesthesia delivery.Proc SPIE2017;10139: 101390S..
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621