1.INRIM, Strada delle Cacce 91, I-10135 Torino, Italy
2.Politecnico di Torino, Corso Duca degli Abruzzi, 24, I-10129 Torino, Italy
3.INFN, Via P. Giuria 1, I-10125 Torino, Italy
A Meda, Email: a.meda@inrim.it
Published:2017-09,
Published Online:28 January 2017,
Received:29 August 2016,
Revised:16 January 2017,
Accepted:24 January 2017
Scan QR Code
Samantaray, N. et al. Realization of the first sub-shot-noise wide field microscope. Light: Science & Applications, 6, e17005 (2017).
Samantaray, N. et al. Realization of the first sub-shot-noise wide field microscope. Light: Science & Applications, 6, e17005 (2017). DOI: 10.1038/lsa.2017.5.
Recently
several proof of principle experiments have demonstrated the advantages of
quantum technologies over classical schemes. The present challenge is to surpass the limits of proof of principle demonstrations to approach real applications. This letter presents such an achievement in the field of quantum enhanced imaging. In particular
we describe the realization of a sub-shot-noise wide field microscope based on spatially multi-mode non-classical photon number correlations in twin beams. The microscope produces realtime images of 8000 pixels at full resolution
for a 500 μm
2
field of view
with noise reduced to 80% of the shot noise level (for each pixel)
which is suitable for absorption imaging of complex structures. By fast post-elaboration
specifically applying a quantum enhanced median filter
the noise can be further reduced (to
<
30% of the shot noise level) by setting a trade-off with the resolution
thus achieving the best sensitivity per incident photon reported in absorption microscopy.
imagingmicroscopyparametric down conversionsub-shot-noise
Taylor MA, Bowen WP. Quantum metrology and its application in biology.Phys Rep2016;615: 1–59..
The LIGO Scientific Collaboration. A gravitational wave observatory operating beyond the quantum shot-noise limit.Nat Phys2011;7: 962–965..
Giovannetti V, Lloyd S, Maccone L. Quantum-enhanced measurements: beating the standard quantum limit.Science2004;306: 1330–1336..
Caves CM. Quantum-mechanical noise in an interferometer.Phys Rev D1981;23: 1693–1708..
Demkowicz-Dobrzański R, Jarzyna M, Kołodyński J. Quantum limits in optical interferometry.Prog Opt2015;60: 345–435..
Genovese M. Real applications of quantum imaging.J Opt2016;18: 073002..
Kolobov MI.Quantum Imaging. New York: Springer; 2007.
Nabors CD, Shelby RM. Two-color squeezing and sub-shot-noise signal recovery in doubly resonant optical parametric oscillators.Phys Rev A1990;42: 556–559..
Souto Ribeiro PH, Schwob C, Maître A, Fabre C. Sub-shot-noise high-sensitivity spectroscopy with optical parametric oscillator twin beams.Opt Lett1997;22: 1893–1895..
Matthews CFJ, Alberto P, Bonneau D, O'Brien JL. Heralding two-photon and four-photon path entanglement on a chip.Phys Rev Lett2011;107: 163602..
Ono T, Okamoto R, Takeuchi S. An entanglement-enhanced microscope.Nat Commun2013;4: 2426..
Israel Y, Rosen S, Silberberg Y. Supersensitive polarization microscopy using NOON states of light.Phys Rev Lett2014;112: 103604..
Wolfgramm F, Vitelli C, Beduini FA, Godbout N, Mitchell MW. Entanglement-enhanced probing of a delicate material system.Nat Photonics2013;7: 28–32..
Crespi A, Lobino M, Matthews JCF, Politi A, Neal CRet al. Measuring protein concentration with entangled photons.Appl Phys Lett2012;100: 233704..
Demkowicz-Dobrzański R, Kołodyński J, Guţă M. The elusive Heisenberg limit in quantum-enhanced metrology.Nat Commun2012;3: 1063..
Mehmet M, Ast S, Eberle T, Steinlechner S, Vahlbruch Het al. Squeezed light at 1550 nm with a quantum noise reduction of 12.3 dB.Opt Express2011;19: 25763–25772..
Armstrong S, Morizur JF, Janousek J, Hage B, Treps Net al. Programmable multimode quantum networks.Nat Commun2012;3: 1026..
Taylor MA, Janousek J, Daria V, Knittel J, Hage Bet al. Biological measurement beyond the quantum limit.Nat Photonics2013;7: 229–233..
Taylor MA, Janousek J, Daria V, Knittel J, Hage Bet al. Subdiffraction-limited quantum imaging within a living cell.Phys Rev X2014;4: 011017..
Treps N, Grosse N, Bowen WP, Fabre C, Bachor HAet al. A quantum laser pointer.Science2003;301: 940–943..
Pooser RC, Lawrie B. Ultrasensitive measurement of microcantilever displacement below the shot-noise limit.Optica2015;2: 393–399..
Wolfgramm F, Cerè A, Beduini FA, Predojevic A, Koschorreck Met al. Squeezed-light optical magnetometry.Phys Rev Lett2010;105: 053601..
Brida G, Caspani L, Gatti A, Genovese M, Meda Aet al. Measurement of sub-shot-noise spatial correlations without background subtraction.Phys Rev Lett2009;102: 213602..
Jedrkiewicz O, Jiang YK, Brambilla E, Gatti A, Bache Met al. Detection of sub-shot-noise spatial correlation in high-gain parametric down conversion.Phys Rev Lett2004;93: 243601..
Mosset A, Devaux F, Lantz E. Spatially noiseless optical amplification of images.Phys Rev Lett2005;94: 223603..
Blanchet JL, Devaux F, Furfaro L, Lantz E. Measurement of sub-shot-noise correlations of spatial fluctuations in the photon-counting regime.Phys Rev Lett2008;101: 233604..
Corzo NV, Marino AM, Jones KM, Lett PD. Noiseless optical amplifier operating on hundreds of spatial modes.Phys Rev Lett2012;109: 043602..
Boyer V, Marino AM, Pooser RC, Lett PD. Entangled images from four-wave mixing.Science2008;321: 544–547..
Brida G, Genovese M, Ruo-Berchera I. Experimental realization of sub-shot-noise quantum imaging.Nat Photonics2010;4: 227–230..
Brambilla E, Caspani L, Jedrkiewicz O, Lugiato LA, Gatti A. High-sensitivity imaging with multi-mode twin beams.Phys Rev A2008;77: 053807..
Brambilla E, Gatti A, Bache M, Lugiato LA. Simultaneous near-field and far-field spatial quantum correlations in the high-gain regime of parametric down-conversion.Phys Rev A2004;69: 023802..
Agafonov IN, Chekhova MV, Leuchs G. Two-color bright squeezed vacuum.Phys Rev A2010;82: 011801..
Davies E.Computer and Machine Vision: Theory, Algorithms, Practicalities. 4th edn. Waltham: Academic Press; 2012.
Brida G, Genovese M, Meda A, Ruo-Berchera I. Experimental quantum imaging exploiting multimode spatial correlation of twin beams.Phys Rev A2011;83: 033811..
Cole R. Live cell imaging: the cell's perspective.Cell Adh Migr2015;8: 452–459..
Pittman TB, Shih YH, Strekalov DV, Sergienko AV. Optical imaging by means of two-photon quantum entanglement.Phys Rev A1995;52: R3429–R3432..
Meyers R, Deacon KS,Shih Y. Ghost-imaging experiment by measuring reflected photons.Phys Rev A2008;77: 041801(R)..
Ferri F, Magatti D, Gatti A, Bache M, Brambilla Eet al. High-resolution ghost image and ghost diffraction experiments with thermal light.Phys Rev Lett2010;94: 183602..
Brida G, Chekhova MV, Fornaro GA, Genovese M, Lopaeva EDet al. Systematic analysis of signal-to-noise ratio in bipartite ghost imaging with classical and quantum light.Phys Rev A2011;83: 063807..
Gatti A, Brambilla E, Bache M, Lugiato LA. Ghost imaging with thermal light: comparing entanglement and classical correlation.Phys Rev Lett2004;93: 093602..
O'Sullivan MN, Chan KW, Boyd RW. Comparison of the signal-to-noise characteristics of quantum versus thermal ghost imaging.Phys Rev A2010;82: 053803..
Morris PA, Aspden RS, Bell JEC, Boyd RW, Padgett MJ. Imaging with a small number of photons.Nat Commun2015;6: 5913..
Lopaeva ED, Ruo-Berchera I, Degiovanni IP, Olivares S, Brida Get al. Experimental realization of quantum illumination.Phys Rev Lett2013;110: 153603..
Phan NM, Cheng MF, Bessarab DA, Krivitsky LA. Interaction of fixed number of photons with retinal rod cells.Phys Rev Lett2014;112: 213601..
Avella A, Ruo-Berchera I, Degiovanni IP, Brida G, Genovese M. Absolute calibration of an EMCCD camera by quantum correlation, linking photon counting to the analog regime.Opt Lett2016;41: 1841–1844..
Meda A, Ruo-Berchera I, Degiovanni IP, Brida G, Rastello MLet al. Absolute calibration of a charge-coupled device camera with twin beams.Appl Phys Lett2014;105: 101113..
Peřina J, Haderka O, Allevi A, Bondani M. Absolute calibration of photon-number-resolving detectors with an analog output using twin beams.Appl Phys Lett2014;104: 041113..
Agafonov IN, Chekhova MV, Iskhakov TS, Penin AN, Rytikov GOet al. Absolute calibration of photodetectors: photocurrent multiplication versus photocurrent subtraction.Opt Lett2011;36: 1329–1331..
Bondani M, Allevi A, Zambra G, Paris MGA, Andreoni A. Sub-shot-noise photon-number correlation in a mesoscopic twin beam of light.Phys Rev A2007;76: 013833..
Perina J Jr, Hamar M, Michálek V, Haderka O. Photon-number distributions of twin beams generated in spontaneous parametric down-conversion and measured by an intensified CCD camera.Phys Rev A2012;85: 023816..
Iskhakov TS, Usenko VC, Andersen UL, Filip R, Chekhova MVet al. Heralded source of bright multi-mode mesoscopic sub-Poissonian light.Opt Lett2016;41: 2149–2152..
Iskhakov TS, Chekhova MV, Leuchs G. Generation and direct detection of broadband mesoscopic polarization-squeezed vacuum.Phys Rev Lett2009;102: 183602..
Tapster PR, Seward SF, Rarity JG. Sub-shot-noise measurement of modulated absorption using parametric down-conversion.Phys Rev A1991;44: 3266–3269..
Whittaker R, Erven C, Neville A, Berry M, O'Brien JLet al. Absorption spectroscopy at the ultimate quantum limit from single-photon states.New J Phys2017;19: 023013..
Simon DS, Jaeger G, Sergienko AV. Quantum information in communication and imaging.Int J Quantum Inform2014;12: 1430004..
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621