Doubling the field of view in off-axis low-coherence interferometric imaging
Original Articles|Updated:2024-09-30
|
Doubling the field of view in off-axis low-coherence interferometric imaging
Doubling the field of view in off-axis low-coherence interferometric imaging
LSA2014年3卷第2期
Affiliations:
Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Tel Aviv 69978, Israel
Author bio:
Dr NT Shaked, Department of Biomedical Engineering, Faculty of Engineering, Tel Aviv University, Ramat Aviv 69978, PO Box 39040, Tel Aviv 69978, Israel E-mail: nshaked@tau.ac.il
Doubling the field of view in off-axis low-coherence interferometric imaging[J]. LSA, 2014,3(2).
Girshovitz, P. & Shaked, N. T. Doubling the field of view in off-axis low-coherence interferometric imaging. Light: Science & Applications, 3, e151 (2014).
Doubling the field of view in off-axis low-coherence interferometric imaging[J]. LSA, 2014,3(2). DOI: 10.1038/lsa.2014.32.
Girshovitz, P. & Shaked, N. T. Doubling the field of view in off-axis low-coherence interferometric imaging. Light: Science & Applications, 3, e151 (2014). DOI: 10.1038/lsa.2014.32.
Doubling the field of view in off-axis low-coherence interferometric imaging
We present a new interferometric and holographic approach
named interferometry with doubled imaging area (IDIA)
with which it is possible to double the camera field of view while performing off-axis interferometric imaging
without changing the imaging parameters
such as the magnification and the resolution. This technique enables quantitative amplitude and phase imaging of wider samples without reducing the acquisition frame rate due to scanning. The method is implemented using a compact interferometric module that connects to a regular digital camera
and is useful in a wide range of applications in which neither the field of view nor the acquisition rate can be compromised. Specifically
the IDIA principle allows doubling the off-axis interferometric field of view
which might be narrower than the camera field of view due to low-coherence illumination. We demonstrate the proposed technique for scan-free quantitative optical thickness imaging of microscopic biological samples
including live neurons and a human sperm cell in rapid motion under high magnification. In addition
we used the IDIA principle to perform non-destructive profilometry during a rapid lithography process of transparent structures.
Girshovitz P, Shaked NT. Generalized cell morphological parameters based on interferometric phase microscopy and their application to cell life cycle characterization.Biomed Opt Exp2012;3: 1757–1773..
Marquet P, Rappaz B, Magistretti PJ, Cuche E, Emery Yet al. Digital holographic microscopy: a noninvasive contrast imaging technique allowing quantitative visualization of living cells with subwavelength axial accuracy.Opt Lett2005;30: 468–470..
Kemper B, Bauwens A, Vollmer A, Ketelhut S, Langehanenberg Pet al. Label-free quantitative cell division monitoring of endothelial cells by digital holographic microscopy.J Biomed Opt2010;15: 036009..
Popescu G, Ikeda T, Dasari RR, Feld MS. Diffraction phase microscopy for quantifying cell structure and dynamics.Opt Lett2006;31: 775–777..
Qu WJ, Choo CO, Yu YJ, Asundi A. Microlens characterization by digital holographic microscopy with physical spherical phase compensation.Appl Opt2010;49: 6448–6454..
Shaked NT. Quantitative phase microscopy of biological samples using a portable interferometer.Opt Lett2012;37: 2016–2018..
Girshovitz P, Shaked NT. Compact and portable low-coherence interferometer with off-axis geometry for quantitative phase microscopy and nanoscopy.Opt Exp2013;21: 5701–5714..
Martínez-León L, Pedrini G, Osten W. Applications of short-coherence digital holography in microscopy.Appl Opt2005;44: 3977–3984..
Monemhaghdoust Z, Montfort F, Emery Y, Depeursinge C, Moser C. Dual wavelength full field imaging in low coherence digital holographic microscopy.Opt Exp2011;19: 24005–24022..
Kolman P, Chmelík R. Coherence-controlled holographic microscope.Opt Exp2010;18: 21990–22003..
Ansari Z, Gu Y, Tziraki M, Jones R, French PM. Elimination of beam walk-off in low-coherence off-axis photorefractive holography.Opt Lett2001;26: 334–336..
Leith EN, Swanson GJ. Achromatic interferometers for white light optical processing and holography.Appl Opt1980;19: 638–644..
Maznev AA, Crimmins TF, Nelson KA. How to make femtosecond pulses overlap.Opt Lett1998;23: 1378–1380..
Uttam S, Goodman NA, Neifeld MA, Kim C, John Ret al. Optically multiplexed imaging with superposition space tracking.Opt Exp2009;17: 1691–1713..
Marcia RF, Kim C, Eldeniz C, Kim J, Brady DJet al. Superimposed video disambiguation for increased field of view.Opt Exp2008;16: 16352–16363..
Brady DJ, Choi K, Marks DL, Horisak R, Lim S. Compressive holography.Opt Exp2009;17: 13040–13049..
Paturzo M, Memmolo P, Tulino A, Finizio A, Ferraro P. Investigation of angular multiplexing and de-multiplexing of digital holograms recorded in microscope configuration.Opt Exp2009;17: 8709–8718..
Ferraro P, Miccio L, Grilli S, Paturzo M, de Nicola Set al. Quantitative phase microscopy of microstructures with extended measurement range and correction of chromatic aberrations by multiwavelength digital holography.Opt Exp2007;15: 14591–14600..
Liu Z, Centurion M, Panotopoulos G, Hong J, Psaltis D. Holographic recording of fast events on a CCD camera.Opt Lett2002;27: 22–24..
Wang X, Zhai H, Mu G. Pulsed digital holography system recording ultrafast process of the femtosecond order.Opt Lett2006;31: 1636–1638..
Gabolde P, Trebino R. Single-shot measurement of the full spatio-temporal field of ultrashort pulses with multi-spectral digital holography.Opt Exp2006;14: 11460–11467..
Liu C, Liu Z, Bo F, Wang Y, Zhu J. Super-resolution digital holographic imaging method.Appl Phys Lett2002;81: 3143–3145..
Paturzo M, Merola F, Grilli S, De Nicola S, Finizio Aet al. Super-resolution in digital holography by a two-dimensional dynamic phase grating.Opt Exp2008;16: 17107–17118..
Micó V, Zalevsky Z, Ferreira C, García J. Superresolution digital holographic microscopy for three-dimensional samples.Opt Exp2008;16: 19260–19270..
Goodman JW.Introduction to Fourier Optics. New York: McGraw-Hill; 1996. pp 295– 392.
Smith DJ, Gaffney EA, Blake JR, Kirkman-Brown JC. Human sperm accumulation near surfaces: a simulation study.J Fluid Mech2009;621: 289–320..
Su TW, Choi I, Feng J, Huang K,McLeod Eet al. Sperm trajectories form chiral ribbons.Sci Rep2013;3: 1664..
Crha I, Zakova J, Huser M, Ventruba P, Lousova Eet al. Digital holographic microscopy in human sperm imaging.J Assist Reprod Gen2011;28: 725–729..
Memmolo P, Di Caprio G, Distante C, Paturzo M, Puglisi Ret al. Identification of bovine sperm head for morphometry analysis in quantitative phase-contrast holographic microscopy.Opt Exp2011;19: 23215–23226..
Katz DF, Dott HM. Methods of measuring swimming speed of spermatozoa.J Reprod Fertil1975;45: 263–272..
Edwards C, Arbabi A, Popescu G, Goddard LL. Optically monitoring and controlling nanoscale topography during semiconductor etching.Light Sci Appl2012;1: e30; doi: 10.1038/lsa.2012.30..