Technical University of Denmark, Department of Micro- and Nanotechnology, DTU Nanotech, DK-2800 Kgs. Lyngby, Denmark
C Vannahme, Technical University of Denmark, Department of Micro- and Nanotechnology, DTU Nanotech, Ørsteds Plads, Building 345E, DK-2800 Kgs. Lyngby, Denmark E-mail: christoph.vannahme@nanotech.dtu.dk
纸质出版日期:2015-06,
网络出版日期:2015-01-13,
收稿日期:2014-10-14,
修回日期:2015-01-10,
录用日期:2015-01-10
Scan QR Code
High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor[J]. LSA, 2015,4(2).
Vannahme, C., Dufva, M. & Kristensen, A. High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor. Light: Science & Applications, 4, e269 (2015).
High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor[J]. LSA, 2015,4(2). DOI: 10.1038/lsa.2015.42.
Vannahme, C., Dufva, M. & Kristensen, A. High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor. Light: Science & Applications, 4, e269 (2015). DOI: 10.1038/lsa.2015.42.
High frame rate and highly sensitive imaging of refractive index changes on a surface is very promising for studying the dynamics of dissolution
mixing and biological processes without the need for labeling. Here
a highly sensitive distributed feedback (DFB) dye laser sensor for high frame rate imaging refractometry without moving parts is presented. DFB dye lasers are low-cost and highly sensitive refractive index sensors. The unique multi-wavelength DFB laser structure presented here comprises several areas with different grating periods. Imaging in two dimensions of space is enabled by analyzing laser light from all areas in parallel with an imaging spectrometer. With this multi-resonance imaging refractometry method
the spatial position in one direction is identified from the horizontal
i.e.
spectral position of the multiple laser lines which is obtained from the spectrometer charged coupled device (CCD) array. The orthogonal spatial position is obtained from the vertical spatial position on the spectrometer CCD array as in established spatially resolved spectroscopy. Here
the imaging technique is demonstrated by monitoring the motion of small sucrose molecules upon dissolution of solid sucrose in water. The omission of moving parts improves the robustness of the imaging system and allows a very high frame rate of up to 12 Hz.
distributed feedback laserlabel-free imaginglaser sensorrefractive index sensor
Min W. Label-free optical imaging of nonfluorescent molecules by stimulated radiation.Curr Opin Chem Biol2011;15: 831–837..
Fan X, White IM, Shopova SI, Zhu H, Suter JDet al. Sensitive optical biosensors for unlabeled targets: a review.Anal Chim Acta2008;620: 8–26..
Fan X, White IM. Optofluidic microsystems for chemical and biological analysis.Nat Photonics2011;5: 591–597..
Nie S, Emroy RE. Probing single molecules and single nanoparticles by surface-enhanced Raman scattering.Science1997;275: 1102–1106..
Zhuo Y, Hu H, Chen W, Lu M, Tian Let al. Single nanoparticle detection using photonic crystal enhanced microscopy.Analyst2014;139: 1007–1015..
Yao J, Stewart ME, Maria J, Lee TW, Gray SKet al. Seeing molecules by eye: surface plasmon resonance imaging at visible wavelengths with high spatial resolution and submonolayer sensitivity.Angew Chem Int Ed2008;47: 5013–5017..
Johansson B, Höök F, Klenerman D, Jönsson P. Label-free measurements of the diffusivity of molecules in lipid membranes.Chemphyschem2014;15: 486–491..
Arroyo JO, Andrecka J, Spillane KM, Billington N, Takagi Yet al. Label-free, all-optical detection, imaging, and tracking of a single protein.Nano Lett2014;14: 2065–2070..
Wang S, Shan X, Patel U, Huang X, Lu Jet al. Label-free imaging, detection, and mass measurement of single viruses by surface plasmon resonance.Proc Natl Acad Sci USA2010;107: 16028–16032..
Lopez CA, Daaboul GG, Vedula RS, Özkumur E, Bergstein DAet al. Label-free, multiplexed virus detection using spectral reflectance imaging.Biosens Bioelectron2011;26: 3432–3437..
Daaboul GG, Yurt A, Zhang X, Hwang GM, Goldberg BBet al. High-throughput detection and sizing of individual low-index nanoparticles and viruses for pathogen identification.Nano Lett2010;10: 4727–4731..
Jamil MM, Denyer MC, Youseffi M, Britland ST, Liu Set al. Imaging of the cell surface interface using objective coupled widefield surface plasmon microscopy.J Struct Biol2008;164: 75–80..
Peterson AW, Halter M, TonaA, Bhadriraju K, Plant AL. Surface plasmon resonance imaging of cells and surface-associated fibronectin.BMC Cell Biol2009;10: 16..
Lidstone EA, Chaudhery V, Kohl A, Chan V, Wolf-Jensen Tet al. Label-free imaging of cell attachment with photonic crystal enhanced microscopy.Analyst2011;136: 3608–3615..
Chen W, Long KD, Lu M,Chaudhery V, Yu Het al. Photonic crystal enhanced microscopy for imaging of live cell adhesion.Analyst2013;138: 5886–5894..
Nazirizadeh Y, Reverey J, Geyer U, Lemmer U, Selhuber-Unkel Cet al. Material-based three-dimensional imaging with nanostructured surfaces.Appl Phys Lett2013;102: 011116..
Danz N, Kick A, Sonntag F, Schmieder S, Höfer Bet al. Surface plasmon resonance platform technology for multi-parameter analyses on polymer chips.Eng Life Sci2011;11: 566–572..
Huang B, Yu F, Zare RN. Surface plasmon resonance imaging using a high numerical aperture microscope objective.Anal Chem2007;79: 2979–2983..
Yang Y, Turnbull G, Samuel ID. Hybrid optoelectronics: a polymer laser pumped by a nitride light-emitting diode.Appl Phys Lett2008;92: 163306..
Cuiffi J, Soong R, Manolakos S, Mohapatra S, Larson D. Nanohole array sensor technology: multiplexed label-free protein binding assays.Proc IFMBE2010;32: 572–575..
Kim K, Yajima J, Oh Y, Lee W, Oowada Set al. Nanoscale localization sampling based on nanoantenna arrays for super-resolution imaging of fluorescent monomers on sliding microtubules.Small2012;8: 892–900..
Gao Y, Xin Z, Zeng B, Gan Q, Cheng Xet al. Plasmonic interferometric sensor arrays for high-performance label-free biomolecular detection.Lab Chip2013;13: 4755–4764..
Ciminelli C, Campanella CM, Dell'Olio F, Campanella CE, Armenise MN. Label-free optical resonant sensors for biochemical applications.Prog Quantum Electron2013;37: 51–107..
Lu M, Choi SS, Wagner CJ, Eden JG, Cunningham BT. Label free biosensor incorporating a replica-molded, vertically emitting distributed feedback laser.Appl Phys Lett2008;92: 261502..
Lu M, Choi SS, Irfan U, Cunningham BT. Plastic distributed feedback laser biosensor.Appl Phys Lett2008;93: 111113..
Ge C, Lu M, Zhang W, Cunningham BT. Distributed feedback laser biosensor incorporating a titanium dioxide nanorod surface.Appl Phys Lett2010;96: 163702..
Grivas C, Pollnau M. Organic solid-state integrated amplifiers and lasers.Laser Photonics Rev2012;6: 419–462..
Heydari E, Buller J, Wischerhoff E, Laschewsky A, Döring Set al. Label-Free biosensor based on an all-polymer DFB laser.Adv Opt Mater2014;2: 137–141..
Vannahme C, Smith CL, Christiansen MB, Kristensen A. Emission wavelength of multilayer distributed feedback dye lasers.Appl Phys Lett2012;101: 151123..
Vannahme C, Leung MC, Richter F, Smith CL, Hermannsson PGet al. Nanoimprinted distributed feedback lasers comprising TiO2thin films: design guidelines for high performance sensing.Laser Photonics Rev2013;7: 1036–1042..
Zhao Z, Mhibik O, Leang T, Forget S, Chénais S. Thermal effects in thin-film organic solid-state lasers.Opt Express2014;22: 30092–30107..
Christiansen MB, Buβ T, Smith CL, Petersen SR, Jørgensen MMet al. Single mode dye-doped polymer photonic crystal lasers.J Micromech Microeng2010;20: 115025..
White IM, Fan X. On the performance quantification of resonant refractive index sensors.Opt Express2008;16: 1020–1028..
Haynes WM, editor.CRC Handbook of Chemistry and Physics. 93rd ed. Boca Raton, FL: CRC Press; 2012.
Block ID, Mathias PC, Jones SI, Vodkin LO, Cunningham BT. Optimizing the spatial resolution of photonic crystal label-free imaging.Appl Opt2009;48: 6567–6574..
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621