1.4th Physics Institute and Research Center SCoPE, University of Stuttgart, D-70569, Stuttgart, Germany
2.IFN-CNR, Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, I-20133, Milan, Italy
3.Institute of Biomaterials and Biomolecular Systems, Dpt. of Molecular Biology and Plant Virology, University of Stuttgart, Pfaffenwaldring 57, D-70569, Stuttgart, Germany
T Steinle, Email: t.steinle@pi4.uni-stuttgart.de
纸质出版日期:2016-12,
网络出版日期:2016-04-07,
收稿日期:2015-12-22,
修回日期:2016-04-01,
录用日期:2016-04-05
Scan QR Code
Synchronization-free all-solid-state laser system for stimulated Raman scattering microscopy[J]. LSA, 2016,5(4).
Steinle, T. et al. Synchronization-free all-solid-state laser system for stimulated Raman scattering microscopy. Light: Science & Applications, 5, e16149 (2016).
Synchronization-free all-solid-state laser system for stimulated Raman scattering microscopy[J]. LSA, 2016,5(4). DOI: 10.1038/lsa.2016.149.
Steinle, T. et al. Synchronization-free all-solid-state laser system for stimulated Raman scattering microscopy. Light: Science & Applications, 5, e16149 (2016). DOI: 10.1038/lsa.2016.149.
We introduce an extremely simple and highly stable system for stimulated Raman scattering (SRS) microscopy. An 8-W
450-fs Yb: KGW bulk oscillator with 41 MHz repetition rate pumps an optical parametric amplifier
which is seeded by a cw tunable external cavity diode laser. The output radiation is frequency doubled in a long PPLN crystal and generates 1.5-ps long narrowband pump pulses that are tunable between 760 and 820 nm with > 50 mW average power. Part of the oscillator output is sent through an etalon and creates Stokes pulses with 100 mW average power and 1.7 ps duration. We demonstrate SRS microscopy at a 30-μs pixel dwell time with high chemical contrast
signal-to-noise ratio in excess of 45 and no need for balanced detection
thanks to the favorable noise properties of the bulk solid-state system. Cw seeding intrinsically ensures low spectral drift. We discuss its application to chemical contrast microscopy of freshly prepared plant tissue sections at different vibrational bands.
label-free imagingstimulated Raman scatteringoptical parametric amplifierspectral compression
Min W, Freudiger CW, Lu SJ, Xie XS. Coherent nonlinear optical imaging: beyond fluorescence microscopy.Annu Rev Phys Chem2011;62: 507–530..
Camp CH, Cicerone MT. Chemically sensitive bioimaging with coherent Raman scattering.Nat Photon2015;9: 295–305..
Pezacki JP, Blake JA, Danielson DC, Kennedy DC, Lyn RKet al. Chemical contrast for imaging living systems: molecular vibrations drive CARS microscopy.Nat Chem Biol2011;7: 137–145..
Yu Y, Ramachandran PV, Wang MC. Shedding new light on lipid functions with CARS and SRS microscopy.Biochim Biophys Acta2014;1841: 1120–1129..
Zumbusch A, Langbein W, Borri P. Nonlinear vibrational microscopy applied to lipid biology.Progress Lipid Res2013;52: 615–632..
Lu FK, Basu S, Igras V, Hoang MP, Ji MBet al. Label-free DNA imagingin vivowith stimulated Raman scattering microscopy.Proc Natl Acad Sci USA2015;112: 11624–11629..
Ji MB, Orringer DA, Freudiger CW, Ramkissoon S, Liu XHet al. Rapid, label-free detection of brain tumors with stimulated Raman scattering microscopy.Sci Transl Med2013;5: 201ra119..
Ji MB, Lewis S, Camelo-Piragua S, Ramkissoon SH, Snuderl Met al. Detection of human brain tumor infiltration with quantitative stimulated Raman scattering microscopy.Sci Transl Med2015;7: 309ra163..
Zumbusch A, Holtom GR, Xie XS. Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering.Phys Rev Lett1999;82: 4142–4145..
Freudiger CW, Min W, Saar BG, Lu SJ, Holtom GRet al. Label-free biomedical imaging with high sensitivity by stimulated Raman scattering microscopy.Science2008;322: 1857–1861..
Nandakumar P, Kovalev A, Volkmer A. Vibrational imaging based on stimulated Raman scattering microscopy.New J Phys2009;11: 033026..
Evans CL, Xie XS. Coherent anti-Stokes Raman scattering microscopy: chemical imaging forbiology and medicine.Annu Rev Anal Chem2008;1: 883–909..
Fu D, Zhou J, Zhu WS, Manley PW, Wang YKet al. Imaging the intracellular distribution of tyrosine kinase inhibitors in living cells with quantitative hyperspectral stimulated Raman scattering.Nat Chem2014;6: 614–622..
Camp CH Jr, Lee YJ, Heddleston JM, Hartshorn CM, Walker ARHet al. High-speed coherent Raman fingerprint imaging of biological tissues.Nat Photon2014;8: 627–634..
Evans CL, Potma EO, Puoris'haag M, Cote D, Lin CPet al. Chemical imaging of tissuein vivowith video-rate coherent anti-Stokes Raman scattering microscopy.Proc Natl Acad Sci USA2005;102: 16807–16812..
Saar BG, Freudiger CW, Reichman J, Stanley CM, Holtom GRet al. Video-rate molecular imagingin vivowith stimulated Raman scattering.Science2010;330: 1368–1370..
Duncan MD, Reintjes J, Manuccia TJ. Scanning coherent anti-Stokes Raman microscope.Opt Lett1982;7: 350–352..
Potma EO, Jones DJ, Cheng JX, Xie XS, Ye J. High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers.Opt Lett2002;27: 1168–1170..
Ganikhanov F, Carrasco S, Xie XS, Katz M, Seitz Wet al. Broadly tunable dual-wavelength light source for coherent anti-Stokes Raman scattering microscopy.Opt Lett2006;31: 1292–1294..
Krauss G, Hanke T, Sell A, Träutlein D, Leitenstorfer Aet al. Compact coherent anti-Stokes Raman scattering microscope based on a picosecond two-color Er: fiber laser system.Opt Lett2009;34: 2847–2849..
Marangoni M, Gambetta A, Manzoni C, Kumar V, Ramponi Ret al. Fiber-format CARS spectroscopy by spectral compression of femtosecond pulses from a single laser oscillator.Opt Lett2009;34: 3262–3264..
Gambetta A, Kumar V, Grancini G, Polli D, Ramponi Ret al. Fiber-format stimulated-Raman-scattering microscopy from a single laser oscillator.Opt Lett2010;35: 226–228..
Freudiger CW, Yang WL, Holtom GR, Peyghambarian N, Xie XSet al. Stimulated Raman scattering microscopy with a robust fibre laser source.Nat Photon2014;8: 153–159..
Coluccelli N, Kumar V, Cassinerio M, Galzerano G, Marangoni Met al. Er/Tm: fiber laser system for coherent Raman microscopy.Opt Lett2014;39: 3090–3093..
Baumgartl M, Chemnitz M, Jauregui C, Meyer T, Dietzek Bet al. All-fiber laser source for CARS microscopy based on fiber optical parametric frequency conversion.Opt Express2012;20: 4484–4493..
Gottschall T, Baumgartl M, Sagnier A, Rothhardt J, Jauregui Cet al. Fiber-based source for multiplex-CARS microscopy based on degenerate four-wave mixing.Opt Express2012;20: 12004–12013..
Chemnitz M, Baumgartl M, Meyer T, Jauregui C, Dietzek Bet al. Widely tuneable fiber optical parametric amplifier for coherent anti-Stokes Raman scattering microscopy.Opt Express2012;20: 26583–26595..
Lefrancois S, Fu D, Holtom GR, Kong LJ, Wadsworth WJet al. Fiber four-wave mixing source for coherent anti-Stokes Raman scattering microscopy.Opt Lett2012;37: 1652–1654..
Lamb ES, Lefrancois S, Ji MB, Wadsworth WJ, Xie XSet al. Fiber optical parametric oscillator for coherent anti-Stokes Raman scattering microscopy.Opt Lett2013;38: 4154–4157..
Nose K, Ozeki Y, Kishi T, Sumimura K, Nishizawa Net al. Sensitivity enhancement of fiber-laser-based stimulated Raman scattering microscopy by collinear balanced detection technique.Opt Express2012;20: 13958–13965..
Steinle T, Kumar V, Steinmann A, Marangoni M, Cerullo Get al. Compact, low-noise, all-solid-state laser system for stimulated Raman scattering microscopy.Opt Lett2015;40: 593–596..
Steinmann A, Metzger B, Hegenbarth R, Giessen H. Compact 7.4W femtosecond oscillator for white-light generation and nonlinear microscopy.Proceedings of the Conference on Lasers and Electro-Optics 2011; paper CThAA5. Baltimore, Maryland, USA: CLEO. 2011.
Steinle T, Kedenburg S, Steinmann A, Giessen H. Combining cw-seeding with highly nonlinear fibers in a broadly tunable femtosecond optical parametric amplifier at 42 MHz.Opt Lett2014;39: 4851–4854..
Manzoni C, Cirmi G, Brida D, De Silvestri S, Cerullo G. Optical-parametric-generation process driven by femtosecond pulses: Timing and carrier-envelope phase properties.Phys Rev A2009;79: 033818..
Marangoni M, Brida D, Quintavalle M, Cirmi G, Pigozzo FMet al. Narrow-bandwidth picosecond pulses by spectral compression of femtosecond pulses in a second-order nonlinear crystal.Opt Express2007;15: 8884–8891..
Evert RF.Esau's Plant Anatomy: Meristems, Cells, and Tissues of the Plant Body - Their Structure, Function, and Development. Hoboken, New Jersey: John Wiley&Sons, Inc., 3rd ed, 2006.
Rimke I, Hehl G, Beutler M, Volz P, Volkmer Aet al. Tunable dual-wavelength two-picosecond light source for coherent Raman scattering microscopy. In: Periasamy A, So PTC, König K editors.Proceedings of SPIE Multiphoton Microscopy in the Biomedical Sciences XIV. San Francisco, CA, USA: SPIE, 2014;8948: 894816..
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621