1.Department of Electrical and Electronic Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong 999077, China
2.Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
3.Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong 999077, China
KK Tsia, Email: tsia@hku.hk
纸质出版日期:2017-03,
网络出版日期:2016-08-12,
收稿日期:2016-04-12,
修回日期:2016-08-04,
录用日期:2016-08-11
Scan QR Code
Ultrafast laser-scanning time-stretch imaging at visible wavelengths[J]. LSA, 2017,6(1).
Wu, J. L. et al. Ultrafast laser-scanning time-stretch imaging at visible wavelengths. Light: Science & Applications, 6, e16196 (2017).
Ultrafast laser-scanning time-stretch imaging at visible wavelengths[J]. LSA, 2017,6(1). DOI: 10.1038/lsa.2016.196.
Wu, J. L. et al. Ultrafast laser-scanning time-stretch imaging at visible wavelengths. Light: Science & Applications, 6, e16196 (2017). DOI: 10.1038/lsa.2016.196.
Optical time-stretch imaging enables the continuous capture of non-repetitive events in real time at a line-scan rate of tens of MHz—a distinct advantage for the ultrafast dynamics monitoring an
d high-throughput screening that are widely needed in biological microscopy. However
its potential is limited by the technical challenge of achieving significant pulse stretching (that is
high temporal dispersion) and low optical loss
which are the critical factors influencing imaging quality
in the visible spectrum demanded in many of these applications. We present a new pulse-stretching technique
termed free-space angular-chirp-enhanced delay (FACED)
with three distinguishing features absent in the prevailing dispersive-fiber-based implementations: (1) it generates substantial
reconfigurable temporal dispersion in free space (
>
1 ns nm
−1
) with low intrinsic loss (
<
6 dB) at visible wavelengths; (2) its wavelength-invariant pulse-stretching operation introduces a new paradigm in time-stretch imaging
which can now be implemented both with and without spectral encoding; and (3) pulse stretching in FACED inherently provides an ultrafast all-optical laser-beam scanning mechanism at a line-scan rate of tens of MHz. Using FACED
we demonstrate not only ultrafast laser-scanning time-stretch imaging with superior bright-field image quality compared with previous work but also
for the first time
MHz fluorescence and colorized time-stretch microscopy. Our results show that this technique could enable a wider scope of applications in high-speed and high-throughput biological microscopy that were once out of reach.
optical time-stretch imagingpulse stretchingultrafast laser scanning
Gao L, Liang JY, Li CY, Wang LV. Single-shot compressed ultrafast photography at one hundred billion frames per second.Nature2014;516: 74–77..
Nakagawa K, Iwasaki A, Oishi Y, Horisaki R, Tsukamoto Aet al. Sequentially timed all-optical mapping photography (STAMP).Nat Photon2014;8: 695–700..
Velten A, Wu D, Adrian J, Belen M, Christopher Bet al. Femto-photography: capturing and visualizing the propagation of light.ACM Trans Graphic2013;32: 44..
Seo M, Boubanga-Tombet S, Yoo J, Ku Z, Gin AVet al. Ultrafast optical wide field microscopy.Opt Express2013;21: 8763–8772..
Goda K, Tsia KK, Jalali B. Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena.Nature2009;458: 1145–1149..
Diebold ED, Buckley BW, Gossett DR, Jalali B. Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy.Nat Photon2013;7: 806–810..
Schneider J, Zahn J, Maglione M, Sigrist SJ, Chojnacki Jet al. Ultrafast, temporally stochastic STED nanoscopy of millisecond dynamics.Nat Methods2015;12: 827–830..
Coppinger F, Bhushan AS, Jalali B. Photonic time stretch and its application to analog-to-digital conversion.IEEE Trans Microw Theory Tech1999;47: 1309–1314..
Goda K, Ayazi A, Gossett DR, Sadasivam J, Lonappan CKet al. High-throughput single-microparticle imaging flow analyzer.Proc Natl Acad Sci USA2012;109: 11630–11635..
Mahjoubfar A, Chen C, Niazi KR, Rabizadeh S, Jalali B. Label-free high-throughput cell screening in flow.Biomed Opt Express2013;4: 1618–1625..
Wong TTW, Lau AKS, Ho KKY, Tang MYH, Robles JDFet al. Asymmetric-detection time-stretch optical microscopy (ATOM) for ultrafast high-contrast cellular imaging in flow.Sci Rep2014;4: 3656..
Lau AKS,Wong TTW, Ho KKY, Tang MTH, Chan ACSet al. Interferometric time-stretch microscopy for ultrafast quantitative cellular and tissue imaging at 1μm.J Biomed Opt2014;19: 076001..
Ugawa M, Lei C, Nozawa T, Ideguchi T, Di Carlo Det al. High-throughput optofluidic particle profiling with morphological and chemical specificity.Opt Lett2015;40: 4803–4806..
Fritzsch FSO, Dusny C, Frick O, Schmid A. Single-cell analysis in biotechnology, systems biology, and biocatalysis.Annu Rev Chem Biomol Eng2012;3: 129–155..
Hoppe PS, Coutu DL, Schroeder T. Single-cell technologies sharpen up mammalian stem cell research.Nat Cell Biol2014;16: 919–927..
Lei C, Guo BS, Cheng ZZ, Goda K. Optical time-stretch imaging: principles and applications.Appl Phys Rev2016;3: 011102..
Lau AKS, Wong TTW, Shum HC, Wong KKY, Tsia KK. Ultrafast microfluidic cellular imaging by optical time-stretch.Imaging Flow Cytometry: Methods and Protocols. New York: Springer; 2016. pp 23–45.
Lau AKS, Tang AHL, Xu JJ, Wei XM, Wong KKYet al. Optical time stretch for high-speed and high-throughput imaging—from single-cell to tissue-wide scales.IEEE J Select Topics Quantum Electron2016;22: 6803115..
Goda K, Jalali B. Dispersive Fourier transformation for fast continuous single-shot measurements.Nat Photon2013;7: 102–112..
Goda K, Mahjoubfar A, Wang C, Fard A, Adam Jet al. Hybrid dispersion laser scanner.Sci Rep2012;2: 445..
Marshall GF, Stutz GE.Handbook of Optical and Laser Scanning, 2nd edn. Boca Raton: CRC Press; 2011.
Choi S, Kim P, Boutilier R, Kim MY, Lee YJet al. Development of a high speed laser scanning confocal microscope with an acquisition rate up to 200 frames per second.Opt Express2013;21: 23611–23618..
Römera GRBE, Bechtold P. Electro-optic and acousto-optic laser beam scanners.Phys Procedia2014;56: 29–39..
Tsia KK, Goda K, Capewell D, Jalali B. Performance of serial time-encoded amplified microscope.Opt Express2010;18: 10016–10028..
Diebold ED, Hon NK, Tan ZW, Chou J, Sienicki Tet al. Giant tunable optical dispersion using chromo-modal excitation of a multimode waveguide.Opt Express2011;19: 23809–23817..
Qiu Y, Xu JJ, Wong KKY, Tsia KK. Exploiting few mode-fibers for optical time-stretch confocal microscopy in the short near-infrared window.Opt Express2012;20: 24115–24123..
Ahn TJ, Park Y, Azaña J. Ultrarapid optical frequency-domain reflectometry based upon dispersion-induced time stretching: principle and applications.IEEE J Select Topics Quantum Electron2012;18: 148–165..
Chen HW, Lei C, Xing FJ, Weng ZL, Chen MHet al. Multiwavelength time-stretch imaging system.Opt Lett2014;39: 2202–2205..
Yazaki A, Kim C, Chan J, Mahjoubfar A, Goda Ket al. Ultrafast dark-field surface inspection with hybrid-dispersion laser scanning.Appl Phys Lett2014;104: 251106..
Wei XM, Lau AKS, Xu YQ, Tsia KK, Wong KKY. 28 MHz swept source at 1.0 μm for ultrafast quantitative phase imaging.Biomed Opt Express2015;6: 3855–3864..
Kärtner FX, Matuschek N, Schibli T, Keller U, Haus HAet al. Design and fabrication of double-chirped mirrors.Opt Lett1997;22: 831–833..
Shirasaki M. Large angular dispersion by a virtually imaged phased array and its application to a wavelength demultiplexer.Opt Lett1996;21: 366–368..
Golubovic B, Austin RR, Steiner-Shepard MK, Reed MK, Diddams SAet al. Double Gires–Tournois interferometer negative-dispersion mirrors for use in tunable mode-locked lasers.Opt Lett2000;25: 275–277..
Greenbaum A, Zhang YB, Feizi A, Chung PL, Luo Wet al. Wide-field computational imaging of pathology slides using lens-free on-chip microscopy.Sci Transl Med2014;6: 267ra175..
Amini H, Lee W, Di Carlo D. Inertial microfluidic physics.Lab Chip2014;14: 2739–2761..
Zhao YB, Tu HH, Liu Y, Bower AJ, Boppart SA. Enhancement of optical coherence microscopy in turbid media by an optical parametric amplifier.J Biophotonics2014;8: 512–521..
Basiji DA, Ortyn WE, Liang LC, Venkatachalam V, Morrissey P. Cellular image analysis and imaging by flow cytometry.Clin Lab Med2007;27: 653–670..
Ghaznavi F, Evans A, Madabhushi A, Feldman M. Digital imaging in pathology: whole-slide imaging and beyond.Annu Rev Pathol2013;8: 331–359..
Chan ACS, Wong TTW, Wong KKY, Lam EY, Tsia KK. Speed-dependent resolution analysis of ultrafast laser-scanning fluorescence microscopy.J Opt Soc Am B2014;3: 755–764..
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621