1.Department of Physics, Chalmers University of Technology, 412 96 Göteborg, Sweden
2.Department of Chemistry and Chemical Engineering, Chalmers University of Technology, 412 96 Göteborg, Sweden
3.Centre of New Technologies, University of Warsaw, Banacha 2c, 02-097 Warsaw, Poland
SS Aćimović, Email: srdjan.acimovic@chalmers.se
M Käll, Email: mikael.kall@chalmers.se
纸质出版日期:2017-09,
网络出版日期:2017-03-10,
收稿日期:2016-11-22,
修回日期:2017-03-02,
录用日期:2017-03-08
Scan QR Code
Superior LSPR substrates based on electromagnetic decoupling for on-a-chip high-throughput label-free biosensing[J]. LSA, 2017,6(3).
Aćimović, S. S. et al. Superior LSPR substrates based on electromagnetic decoupling for on-a-chip high-throughput label-free biosensing. Light: Science & Applications, 6, e17042 (2017).
Superior LSPR substrates based on electromagnetic decoupling for on-a-chip high-throughput label-free biosensing[J]. LSA, 2017,6(3). DOI: 10.1038/lsa.2017.42.
Aćimović, S. S. et al. Superior LSPR substrates based on electromagnetic decoupling for on-a-chip high-throughput label-free biosensing. Light: Science & Applications, 6, e17042 (2017). DOI: 10.1038/lsa.2017.42.
Localized surface plasmon resonance (LSPR) biosensing based on supported metal nanoparticles offers unparalleled possibilities for high-end miniaturization
multiplexing and high-throughput label-free molecular interaction analysis in real time when integrated within an opto-fluidic environment. However
such LSPR-sensing devices typically contain extremely large regions of dielectric materials that are open to molecular adsorption
which must be carefully blocked to avoid compromising the device readings. To address this issue
we made
the support essentially invisible to the LSPR by carefully removing the dielectric material overlapping with the localized plasmonic fields through optimized wet-etching. The resulting LSPR substrate
which consists of gold nanodisks centered on narrow SiO
2
pillars
exhibits markedly reduced vulnerability to nonspecific substrate adsorption
thus allowing
in an ideal case
the implementation of thicker and more efficient passivation layers. We demonstrate that this approach is effective and fully compatible with state-of-the-art multiplexed real-time biosensing technology and thus represents the ideal substrate design for high-throughput label-free biosensing systems with minimal sample consumption.
biosensinghyperspectrallab-on-a-chipLSPRnonspecific adsorption
Lundström I. From a laboratory exercise for students to a pioneering biosensing technology.Plasmonics2014;9: 741–751..
Homola J. Surface plasmon resonance sensors for detection of chemical and biological species.Chem Rev2008;108: 462–493..
Anker JN, Hall WP, Lyandres O, Shah NC, Zhao Jet al. Biosensing with plasmonic nanosensors.Nat Mater2008;7: 442–453..
Aćimović SS, Kreuzer MP, González MU, Quidant R. Plasmon near-field coupling in metal dimers as a step toward single-molecule sensing.ACS Nano2009;3: 1231–1237..
Luk'yanchuk B, Zheludev NI, Maier SA, Halas NJ, Nordlander Pet al. The Fano resonance in plasmonic nanostructures and metamaterials.Nat Mater2010;9: 707–715..
Jonsson MP, Dahlin AB, Feuz L, Petronis S, Höök F. Locally functionalized short-range ordered nanoplasmonic pores for bioanalytical sensing.Anal Chem2010;82: 2087–2094..
Cetin AE, Altug H. Fano resonant ring/disk plasmonic nanocavities on conducting substrates for advanced biosensing.ACS Nano2012;6: 9989–9995..
McPhillips J, Murphy A, Jonsson MP, Hendren WR, Atkinson Ret al. High-performance biosensing using arrays of plasmonic nanotubes.ACS Nano2010;4: 2210–2216..
Shen Y, Zhou JH, Liu TR, Tao YT, Jiang RBet al. Plasmonic gold mushroom arrays with refractive index sensing figures of merit approaching the theoretical limit.Nat Commun2013;4: 2381..
Svedendahl M, Chen S, Dmitriev A, Käll M. Refractometric sensing using propagating versus localized surface plasmons: a direct comparison.Nano Lett2009;9: 4428–4433..
Ament I, Prasad J, Henkel A, Schmachtel S, Sönnichsen C. Single unlabeled protein detection on individual plasmonic nanoparticles.Nano Lett2012;12: 1092–1095..
Beuwer MA, Prins MW, Zijlstra P. Stochastic protein interactions monitored by hundreds of single-molecule plasmonic biosensors.Nano Lett2015;15: 3507–3511..
Dahlin AB. Size matters: problems and advantages associated with highly miniaturized sensors.Sensors2012;12: 3018–3036..
Šípová H, Vrba D, Homola J. Analytical value of detecting an individual molecular binding event: the case of the surface plasmon resonance biosensor.Anal Chem2011;84: 30–33..
Thorsen T, Maerkl SJ, Quake SR. Microfluidic large-scale integration.Science2002;298: 580–584..
Garcia-Cordero JL, Maerkl SJ. A 1024-sample serum analyzer chip for cancer diagnostics.Lab Chip2014;14: 2642–2650..
Marie R, Dahlin AB, Tegenfeldt JO, Höök F. Generic surface modification strategy for sensing applications based on Au/SiO2 nanostructures.Biointerphases2007;2: 49–55..
Marie R, Beech JP, Vörös J, Tegenfeldt JO, Höök F. Use of PLL-g-PEG in micro-fluidic devices for localizing selective and specific protein binding.Langmuir2006;22: 10103–10108..
Huang B, Wu HK, Kim S, Zare RN. Coating of poly (dimethylsiloxane) with n-dodecyl-β-D-maltoside to minimize nonspecific protein adsorption.Lab Chip2005;5: 1005–1007..
Viefhues M, Manchanda S, Chao T-C, Anselmetti D, Regtmeier Jet al. Physisorbed surface coatings for poly (dimethylsiloxane) and quartz microfluidic devices.Anal Bioanal Chem2011;401: 2113–2122..
Boozer C, Yu QM, Chen SF, Lee C-Y, Homola Jet al. Surface functionalization for self-referencing surface plasmon resonance (SPR) biosensors by multi-step self-assembly.Sensors Actuat B Chem2003;90: 22–30..
Keefe AJ, Brault ND, Jiang SY. Suppressing surface reconstruction of superhydrophobic PDMS using a superhydrophilic zwitterionic polymer.Biomacromolecules2012;13: 1683–1687..
Hua BY, Han KY, Zhou RB, Kim H, Shi XHet al. An improved surface passivation method for single-molecule studies.Nat Methods2014;11: 1233–1236..
Norde W. Driving forces for protein adsorption at solid surfaces.Macromol Symp1996;103: 5–18..
Lee JN, Park C, Whitesides GM. Solvent compatibility of poly (dimethylsiloxane)-based microfluidic devices.Anal Chem2003;75: 6544–6554..
Dmitriev A, Hägglund C, Chen S, Fredriksson H, Pakizeh Tet al. Enhanced nanoplasmonic optical sensors with reduced substrate effect.Nano Lett2008;8: 3893–3898..
Chen PY, Chung MT, McHugh W, Nidetz R, Li YWet al. Multiplex serum cytokine immunoassay using nanoplasmonic biosensor microarrays.ACS Nano2015;9: 4173–4181..
Verellen N, Van Dorpe P, Huang CJ, Lodewijks K, Vandenbosch GAEet al. Plasmon line shaping using nanocrosses for high sensitivity localized surface plasmon resonance sensing.Nano Lett2011;11: 391–397..
Otte MA, Estévez M-C, Carrascosa LG, González-Guerrero AB, Lechuga LMet al. Improved biosensing capability with novel suspended nanodisks.J Phys Chem C2011;115: 5344–5351..
Cetin AE, Etezadi D, Altug H. Accessible nearfields by nanoantennas on nanopedestals for ultrasensitive vibrational spectroscopy.Adv Opt Mater2014;2: 866–872..
Acimovic SS Localized surface plasmon resonance for biosensing lab-on-a-chip applications. PhD thesis, Universitat Politècnica de Catalunya, Castelldefels, Spain, 2012.
Aćimović SS, Ortega MA, Sanz V, Berthelot J, Garcia-Cordero JLet al. LSPR chip for parallel, rapid, and sensitive detection of cancer markers in serum.Nano Lett2014;14: 2636–2641..
Ruemmele JA, Hall WP, Ruvuna LK, Van Duyne RP. A localized surface plasmon resonance imaging instrument for multiplexed biosensing.Anal Chem2013;85: 4560–4566..
Yoshikawa H, Murahashi M, Saito M, Jiang S, Iga Met al. Parallelized label-free detection of protein interactions using a hyper-spectral imaging system.Anal Methods2015;7: 5157–5161..
Johnson PB, Christy R-W. Optical constants of the noble metals.Phys Rev B1972;6: 4370–4379..
Cheng T-L, Cheng C-M, Chen B-M, Tsao D-A, Chuang K-Het al. Monoclonal antibody-based quantitation of poly (ethylene glycol)-derivatized proteins, liposomes, and nanoparticles.Bioconjugate Chem2005;16: 1225–1231..
Hanarp P, Käll M, Sutherland DS. Optical properties of short range ordered arrays of nanometer gold disks prepared by colloidal lithography.J Phys Chem B2003;107: 5768–5772..
Andersson A-S, Glasmästar K, Hanarp P, Seantier B, Sutherland DS. Patterning colloidal monolayer films using microcontact particle stripping.Nanotechnology2007;18: 205303..
Dahlin AB, Tegenfeldt JO, Höök F. Improving the instrumental resolution of sensors based on localized surface plasmon resonance.Anal Chem2006;78: 4416–4423..
Junesch J, Emilsson G, Xiong KL, Kumar S, Sannomiya Tet al. Location-specific nanoplasmonic sensing of biomolecular binding to lipid membranes with negative curvature.Nanoscale2015;7: 15080–15085..
Emilsson G, Schoch RL, Feuz L, Höök F, Lim RYHet al. Strongly stretched protein resistant poly (ethylene glycol) brushes prepared by grafting-to.ACS Appl Mater Interfaces2015;7: 7505–7515..
Rosano C, Arosio P, Bolognesi M. The X-ray three-dimensional structure of avidin.Biomol Eng1999;16: 5–12..
Lee SH, Lindquist NC, Wittenberg NJ, Jordan LR, Oh S-H. Real-time full-spectral imaging and affinity measurements from 50 microfluidic channels using nanohole surface plasmon resonance.Lab Chip2012;12: 3882–3890..
Im H, Shao HL, Park YI, Peterson VM, Castro CMet al. Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor.Nat Biotechnol2014;32: 490–495..
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621