1.State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan 030006, China
2.Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China
3.PolySense Lab, Dipartimento Interateneo di Fisica, University and Politecnico of Bari, CNR-IFN, Via Amendola 173, 70126 Bari, Italy
Lei Dong (donglei@sxu.edu.cn)
收稿日期:2023-10-31,
修回日期:2024-03-11,
录用日期:2024-03-12,
网络出版日期:2024-03-22,
纸质出版日期:2024-04-30
Scan QR Code
Quartz-enhanced multiheterodyne resonant photoacoustic spectroscopy[J]. LSA, 2024,13(4):696-705.
Wang, J. P. et al. Quartz-enhanced multiheterodyne resonant photoacoustic spectroscopy. Light: Science & Applications, 13, 696-705 (2024).
Quartz-enhanced multiheterodyne resonant photoacoustic spectroscopy[J]. LSA, 2024,13(4):696-705. DOI: 10.1038/s41377-024-01425-1.
Wang, J. P. et al. Quartz-enhanced multiheterodyne resonant photoacoustic spectroscopy. Light: Science & Applications, 13, 696-705 (2024). DOI: 10.1038/s41377-024-01425-1.
The extension of dual-comb spectroscopy (DCS) to all wavelengths of light along with its ability to provide ultra-large dynamic range and ultra-high spectral resolution
renders it extremely useful for a diverse array of applications in physics
chemistry
atmospheric science
space science
as well as medical applications. In this work
we report on an innovative technique of quartz-enhanced multiheterodyne resonant photoacoustic spectroscopy (QEMR-PAS)
in which the beat frequency response from a dual comb is frequency down-converted into the audio frequency domain. In this way
gas molecules act as an optical-acoustic converter through the photoacoustic effect
generating heterodyne sound waves.
Unlike conventional DCS
where the light wave is detected by a wavelength-dependent photoreceiver
QEMR-PAS employs a quartz tuning fork (QTF) as a high-
Q
sound transducer and works in conjunction with a phase-sensitive detector to extract the resonant sound component from the multiple heterodyne acoustic tones
resulting in a straightforward and low-cost hardware configuration. This novel QEMR-PAS technique enables wavelength-independent DCS detection for gas sensing
providing an unprecedented dynamic range of 63 dB
a remarkable spectral resolution of 43 MHz (or ~0.3 pm)
and a prominent noise equivalent absorption of 5.99 × 10
-6
cm
-1
·Hz
-1/2
.
Coddington, I., Newbury, N. & Swann, W. Dual-comb spectroscopy. Optica 3 , 414–426 (2016)..
Picqué, N. & Hänsch, T. W. Frequency comb spectroscopy. Nat. Photonics 13 , 146–157 (2019)..
Schiller, S. Spectrometry with frequency combs. Opt. Lett. 27 , 766–768, (2002)..
Okubo, S. et al. Near-infrared broadband dual-frequency-comb spectroscopy with a resolution beyond the Fourier limit determined by the observation time window. Opt. Express 23 , 33184–33193, (2015)..
Hoghooghi, N. et al. Broadband 1-GHz mid-infrared frequency comb. Light Sci. Appl. 11 , 264 (2022)..
Brehm, M., Schliesser, A. & Keilmann, F. Spectroscopic near-field microscopy using frequency combs in the mid-infrared. Opt. Expr. 14 , 11222–11233 (2006)..
Pistore, V. et al. Self-induced phase locking of terahertz frequency combs in a phase‐sensitive hyperspectral near‐field nanoscope. Adv. Sci. 9 , 2200410 (2022)..
Baumann, E. et al. Spectroscopy of the methane ν 3 band with an accurate midinfrared coherent dual-comb spectrometer. Phys. Rev. A 84 , 062513 (2011)..
Cassinerio, M. et al. Absolute dual-comb spectroscopy at 1.55 μm by free-running Er: fiber lasers. Appl. Phys. Lett. 104 , 231102 (2014)..
Vicentini, E. et al. Dual-comb hyperspectral digital holography. Nat. Photonics 15 , 890–894 (2021)..
Ideguchi, T. et al. Coherent Raman spectro-imaging with laser frequency combs. Nature 502 , 355–358 (2013)..
Rieker, G. B. et al. Frequency-comb-based remote sensing of greenhouse gases over kilometer air paths. Optica 1 , 290–298, (2014)..
Ycas, G. et al. Compact mid-infrared dual-comb spectrometer for outdoor spectroscopy. Opt. Express 28 , 14740–14752, (2020)..
Wang, Q. et al. Dual-comb photothermal spectroscopy. Nat. Commun. 13 , 2181 (2022)..
Coddington, I., Swann, W. & Newbury, N. Coherent dual-comb spectroscopy at high signal-to-noise ratio. Phys. Rev. A 82 , 043817 (2010)..
Yasui, T. et al. Super-resolution discrete Fourier transform spectroscopy beyond time-window size limitation using precisely periodic pulsed radiation. Optica 2 , 460–467, (2015)..
Demtröder, W. Laser Spectroscopy. (Heidelberg: Springer, 1982).
Svanberg,S. Atomic and Molecular Spectroscopy: Basic Aspects and Practical Applications. (Heidelberg: Springer, 2012).
Rösch, M. et al. On-chip, self-detected terahertz dual-comb source. Appl. Phys. Lett. 108 , 171104 (2016)..
Muraviev, A. V. et al. Massively parallel sensing of trace molecules and their isotopologues with broadband subharmonic mid-infrared frequency combs. Nat. Photonics 12 , 209–214 (2018)..
Sterczewski, L. A. et al. Terahertz hyperspectral imaging with dual chip-scale combs. Optica 6 , 766–771 (2019)..
Wei, T. T. et al. High and flat spectral responsivity of quartz tuning fork used as infrared photodetector in tunable diode laser spectroscopy. Appl. Phys. Rev. 8 , 041409 (2021)..
Sadiek, I. et al. Optical frequency comb photoacoustic spectroscopy. Phys. Chem. Chem. Phys. 20 , 27849–27855 (2018)..
Wildi, T. et al. Photo-acoustic dual-frequency comb spectroscopy. Nat. Commun. 11 , 1–6 (2020)..
Friedlein, J. T. et al. Dual-comb photoacoustic spectroscopy. Nat. Commun. 11 , 3152 (2020)..
Kosterev, A. A. et al. Quartz-enhanced photoacoustic spectroscopy. Opt. Lett. 27 , 1902–190 4, (2002)..
Wu, H. P. et al. Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring. Nat. Commun. 8 , 15331 (2017)..
Milde, T. et al. QEPAS sensor for breath analysis: a behavior of pressure. Appl. Opt. 57 , C120–C127 (2018)..
Yi, H. M. et al. T-shape microresonator-based high sensitivity quartz-enhanced photoacoustic spectroscopy sensor. Opt. Express 20 , 9187–9196, (2012)..
Kosterev, A. A. et al. Applications of quartz tuning forks in spectroscopic gas sensing. Rev. Sci. Instrum. 76 , 043105 (2005)..
Blaauwgeers, R. et al. Quartz tuning fork: Thermometer, pressure-and viscometer for helium liquids. J. Low. Temp. Phys. 146 , 537–562 (2007)..
Wu, H. P. et al. Enhanced near-infrared QEPAS sensor for sub-ppm level H 2 S detection by means of a fiber amplified 1582 nm DFB laser. Sens. Actuators, B 221 , 666–672 (2015)..
Cui, R. Y. et al. Generalized optical design of two-spherical-mirror multi-pass cells with dense multi-circle spot patterns. Appl. Phys. Lett. 116 , 091103 (2020)..
Ren, X. Y. et al. Dual-comb quartz-enhanced photoacoustic spectroscopy. Photoacoustics 28 , 100403 (2022)..
Schibli, T. R. et al. Optical frequency comb with submillihertz linewidth and more than 10 W average power. Nat. Photonics 2 , 355–359 (2008)..
Cingöz, A. et al. Direct frequency comb spectroscopy in the extreme ultraviolet. Nature 482 , 68–71 (2012)..
Yan, M. et al. Mid-infrared dual-comb spectroscopy with electro-optic modulators. Light Sci. Appl. 6 , e17076 (2017)..
Martín-Mateos, P. et al. Frequency accurate coherent electro-optic dual-comb spectroscopy in real-time. Opt. Expr. 26 , 9700–9713 (2018)..
Nitzsche, L. et al. Tunable dual-comb spectrometer for mid-infrared trace gas analysis from 3 to 4.7 μm. Opt. Expr. 29 , 25449–25461 (2021)..
0
浏览量
5
Downloads
1
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621