Kho, A. M. et al. Incoherent excess noise spectrally encodes broadband light sources. Light: Science & Applications, 9, 1322-1330 (2020).
Kho, A. M. et al. Incoherent excess noise spectrally encodes broadband light sources. Light: Science & Applications, 9, 1322-1330 (2020). DOI: 10.1038/s41377-020-00404-6.
Across optics and photonics
excess intensity noise is often considered a liability. Here
we show that excess noise in broadband supercontinuum and superluminescent diode light sources encodes each spectral channel with unique intensity fluctuations
which actually serve a useful purpose. Specifically
we report that excess noise correlations can both characterize the spectral resolution of spectrometers and enable cross-calibration of their wavelengths across a broad bandwidth. Relative to previous methods that use broadband interferometry and narrow linewidth lasers to characterize and calibrate spectrometers
our approach is simple
comprehensive
and rapid enough to be deployed during spectrometer alignment. First
we employ this approach to aid alignment and reduce the depth-dependent degradation of the sensitivity and axial resolution in a spectrometer-based optical coherence tomography (OCT) system
revealing a new outer retinal band. Second
we achieve a pixel-to-pixel correspondence between two otherwise disparate spectrometers
enabling a robust comparison of their respective measurements. Thus
excess intensity noise has useful applications in optics and photonics.
Fercher, A. F. et al. Measurement of intraocular distances by backscattering spectral interferometry.Opt. Commun.117, 43–48 (1995)..
Lu, G. L.&Fei, B. W. Medical hyperspectral imaging: a review.J. Biomed. Opt.19, 010901 (2014)..
Long, D. A.Raman Spectroscopy(McGraw-Hill, New York, 1977).
Reeves, J. B. III Near-versus mid-infrared diffuse reflectance spectroscopy for soil analysis emphasizing carbon and laboratory versus on-site analysis: Where are we and what needs to be done?Geoderma158, 3–14 (2010)..
Bol'Shakov, A. A. et al. Laser-induced breakdown spectroscopy in industrial and security applications.Appl. Opt.49, C132–C142 (2010)..
Yun, S. H. et al. High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength.Opt. Express11, 3598–3604 (2003)..
Leitgeb, R., Hitzenberger, C. K.&Fercher, A. F. Performance of fourier domain vs. time domain optical coherence tomography.Opt. Express11, 889–894 (2003)..
Dorrer, C. et al. Spectral resolution and sampling issues in Fourier-transform spectral interferometry.J. Optical Soc. Am. B17, 1795–1802 (2000)..
Alfano, R. R. The Supercontinuum Laser Source. (Springer, New York, 2006).
Brown, W. J., Kim, S.&Wax, A. Noise characterization of supercontinuum sources for low-coherence interferometry applications.J. Optical Soc. Am. A31, 2703–2710 (2014)..
Corwin, K. L. et al. Fundamental amplitude noise limitations to supercontinuum spectra generated in a microstructured fiber.Appl. Phys. B77, 269–277 (2003)..
Mandel, L. Fluctuations of photon beams and their correlations.Proc. Phys. Soc.72, 1037–1048 (1958)..
Park, B. H. et al. Real-time fiber-based multi-functional spectral-domain optical coherence tomography at 1.3 µm.Opt. Express13, 3931–3944 (2005)..
Götzinger, E., Pircher, M.&Hitzenberger, C. K. High speed spectral domain polarization sensitive optical coherence tomography of the human retina.Opt. Express13, 10217–10229 (2005)..
Chong, S. P. et al. Quantitative microvascular hemoglobin mapping using visible light spectroscopic optical coherence tomography.Biomed. Opt. Express6, 1429–1450 (2015)..
Makita, S., Fabritius, T.&Yasuno, Y. Full-range, high-speed, high-resolution 1-µm spectral-domain optical coherence tomography using BM-scan for volumetric imaging of the human posterior eye.Opt. Express16, 8406–8420 (2008)..
de Boer, J. F. et al. Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography.Opt. Lett.28, 2067–2069 (2003)..
Choma, M. A. et al. Sensitivity advantage of swept source and Fourier domain optical coherence tomography.Opt. Express11, 2183–2189 (2003)..
Shin, S. et al. Characterization and analysis of relative intensity noise in broadband optical sources for optical coherence tomography.IEEE Photonics Technol. Lett.22, 1057–1059 (2010)..
Kho, A.&Srinivasan, V. J. Compensating spatially dependent dispersion in visible light OCT.Opt. Lett.44, 775–778 (2019)..
van Rossum, A. G. S. H. et al. Pals1/Mpp5 is required for correct localization of Crb1 at the subapical region in polarized Müller glia cells.Hum. Mol. Genet.15, 2659–2672 (2006)..
West, E. L. et al. Pharmacological disruption of the outer limiting membrane leads to increased retinal integration of transplanted photoreceptor precursors.Exp. Eye Res.86, 601–611 (2008)..
Kocaoglu, O. P. et al. Adaptive optics optical coherence tomography at 1 MHz.Biomed. Opt. Express5, 4186–4200 (2014)..
Goodman, J. W. Statistical properties of laser speckle patterns. InLaser Speckle and Related Phenomena(ed. Dainty, J. C.) 9–75 (Berlin, Heidelberg, Springer, 1975).
Boas, D. A.&Dunn, A. K. Laser speckle contrast imaging in biomedical optics.J. Biomed. Opt.15, 011109 (2010)..
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621