
1.Skolkovo Institute of Science and Technology, 3 Nobelya str., Moscow 121205, Russia
2.Department of Electrical Engineering, Tel Aviv University, Ramat Aviv, Tel Aviv 69978, Israel
3.Light-Matter Interaction Centre, Tel Aviv University, Ramat Aviv, Tel Aviv 69978, Israel
4.Saratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia
5.Tomsk State University, 36 Lenin's av., Tomsk 634050, Russia
6.M.V. Lomonosov Moscow State University, Leninskie Gory, 1-3, Moscow 119992, Russia
7.SPE LLC Nanostructured Glass Technology, 101 50 Let Oktjabrja, Saratov 410033, Russia
8.Center for Photonics and 2D Materials, Moscow Institute of Physics and Technology, Dolgoprudny 141700, Russia
9.Institute of Precision Mechanics and Control of the Russian Academy of Sciences, 24 Rabochaya str., Saratov 410028, Russia
Dmitry A. Gorin (d.gorin@skoltech.ru)
Published:2020,
Published Online:10 October 2020,
Received:12 May 2020,
Revised:17 September 2020,
Accepted:24 September 2020
Scan QR Code
Ermatov, T. et al. Multispectral sensing of biological liquids with hollow-core microstructured optical fibres. Light: Science & Applications, 9, 1661-1672 (2020).
Ermatov, T. et al. Multispectral sensing of biological liquids with hollow-core microstructured optical fibres. Light: Science & Applications, 9, 1661-1672 (2020). DOI: 10.1038/s41377-020-00410-8.
The state of the art in optical biosensing is focused on reaching high sensitivity at a single wavelength by using any type of optical resonance. This common strategy
however
disregards the promising possibility of simultaneous measurements of a bioanalyte's refractive index over a broadband spectral domain. Here
we address this issue by introducing the approach of in-fibre multispectral optical sensing (IMOS). The operating principle relies on detecting changes in the transmission of a hollow-core microstructured optical fibre when a bioanalyte is streamed through it via liquid cells. IMOS offers a unique opportunity to measure the refractive index at 42 wavelengths
with a sensitivity up to ~3000 nm per refractive index unit (RIU) and a figure of merit reaching 99 RIU
−1
in the visible and near-infra-red spectral ranges. We apply this technique to determine the concentration and refractive index dispersion for bovine serum albumin and show that the accuracy meets clinical needs.
Quesada-González, D.&Merkoçi, A. Nanomaterial-based devices for point-of-care diagnostic applications.Chem. Soc. Rev.47, 4697–4709 (2018)..
Xu, Y. et al. Optical refractive index sensors with plasmonic and photonic structures: promising and inconvenient truth.Adv. Optical Mater.7, 1801433 (2019)..
Chen, G. Y. et al. Nanochemistry and nanomedicine for nanoparticle-based diagnostics and therapy.Chem. Rev.116, 2826–2885 (2016)..
Cubillas, A. M. et al. Photonic crystal fibres for chemical sensing and photochemistry.Chem. Soc. Rev.42, 8629–8648 (2013)..
Farka, Z. et al. Nanoparticle-based immunochemical biosensors and assays: recent advances and challenges.Chem. Rev.117, 9973–10042 (2017)..
Shandilya, R. et al. Nanobiosensors: point-of-care approaches for cancer diagnostics.Biosens. Bioelectron.130, 147–165 (2019)..
Sreekanth, K. V. et al. Extreme sensitivity biosensing platform based on hyperbolic metamaterials.Nat. Mater.15, 621–627 (2016)..
Yesilkoy, F. et al. Ultrasensitive hyperspectral imaging and biodetection enabled by dielectric metasurfaces.Nat. Photonics13, 390–396 (2019)..
Wang, Z. Tissue refractive index as marker of disease.J. Biomed. Opt.16, 116017 (2011)..
Mazarevica, G., Freivalds, T.&Jurka, A. Properties of erythrocyte light refraction in diabetic patients.J. Biomed. Opt.7, 244 (2002)..
Goldwasser, P.&Feldman, J. Association of serum albumin and mortality risk.J. Clin. Epidemiol.50, 693–703 (1997)..
Liu, Z. B.&Chen, X. Y. Simple bioconjugate chemistry serves great clinical advances: albumin as a versatile platform for diagnosis and precision therapy.Chem. Soc. Rev.45, 1432–1456 (2016)..
Lazareva, E. N.&Tuchin, V. V. Measurement of refractive index of hemoglobin in the visible/NIR spectral range.J. Biomed. Opt.23, 1–9 (2018)..
Zysk, A. M., Chaney, E. J.&Boppart, S. A. Refractive index of carcinogen-induced rat mammary tumours.Phys. Med. Biol.51, 2165–2177 (2006)..
Zhernovaya, O. S., Tuchin, V. V.&Meglinski, I. V. Monitoring of blood proteins glycation by refractive index and spectral measurements.Laser Phys. Lett.5, 460–464 (2008)..
Lee, S. et al. Refractive index tomograms and dynamic membrane fluctuations of red blood cells from patients with diabetes mellitus.Sci. Rep.7, 1039 (2017)..
Busher, J. T. Serum albumin and globulin. InClinical Methods: The History, Physical, and Laboratory Examinations(eds. Walker, H. K. et al.) 479–499 (Butterworths, 1990).
Duly, E. B. et al. Measurement of serum albumin by capillary zone electrophoresis, bromocresol green, bromocresol purple, and immunoassay methods.J. Clin. Pathol.56, 780–781 (2003)..
Yu, W. Y. et al. Cavity optomechanical spring sensing of single molecules.Nat. Commun.7, 12311 (2016)..
Zheltikov, A. M. METHODOLOGICAL NOTES: Colors of thin films, antiresonant phenomena in optical systems, and the limiting loss of modes in hollow optical waveguides.Phys. Uspekhi51, 591–600 (2008)..
Noskov, R. E. et al. Enabling magnetic resonance imaging of hollow-core microstructured optical fibers via nanocomposite coating.Opt. Express27, 9868–9878 (2019)..
Ermatov, T. et al. Microstructured optical waveguide-based endoscopic probe coated with silica submicron particles.Materials12, 1424 (2019)..
Zhang, L., Guo, H. Y.&Sun, J. Q. Salt effects on the structural tailoring of layer-by-layer assembled polyelectrolyte complexes and salt-containing polyelectrolyte films.Thin Solid Films653, 258–266 (2018)..
Kolasińska, M.&Warszyński, P. The effect of support material and conditioning on wettability of PAH/PSS multilayer films.Bioelectrochemistry66, 65–70 (2005)..
Kolasińska, M.&Warszyński, P. The effect of nature of polyions and treatment after deposition on wetting characteristics of polyelectrolyte multilayers.Appl. Surf. Sci.252, 759–765 (2005)..
Decher, G. Fuzzy nanoassemblies: toward layered polymeric multicomposites.Science277, 1232–1237 (1997)..
De Villiers, M. M. et al. Introduction to nanocoatings produced by layer-by-layer (LbL) self-assembly.Adv. Drug Deliv. Rev.63, 701–715 (2011)..
Hoogeveen, N. G. et al. Formation and stability of multilayers of polyelectrolytes.Langmuir12, 3675–3681 (1996)..
Neff, P. A. et al. Electrical detection of self-assembled polyelectrolyte multilayers by a thin film resistor.Macromolecules39, 463–466 (2006)..
Arys, X. et al. Ultrathin multilayers made by alternate deposition of ionenes and polyvinylsulfate: From unstable to stable growth.Thin Solid Films327–329, 734–738 (1998)..
El Haitami, A. E. et al. Effect of the supporting electrolyte anion on the thickness of PSS/PAH multilayer films and on their permeability to an electroactive probe.Langmuir25, 2282–2289 (2009)..
Feldötö, Z., Varga, I.&Blomberg, E. Influence of salt and rinsing protocol on the structure of PAH/PSS polyelectrolyte multilayers.Langmuir26, 17048–17057 (2010)..
Toda, M. et al. Surface stress, thickness, and mass of the first few layers of polyelectrolyte.Langmuir24, 3191–3198 (2008)..
Kang, S., Day, D. E.&Stoffer, J. O. Measurement of the refractive index of glass fibers by the Christiansen-Shelyubskii method.J. Non-Crystalline Solids220, 299–308 (1997)..
Tompkins, H. G., Smith, S.&Convey, D. Optimizing the ellipsometric analysis of a transparent layer on glass.Surf. Interface Anal.29, 845–850 (2000)..
Wang, D. et al. Layer-by-layer assembled transparent polymeric adhesive films with adjustable refractive indices.Int. J. Adhes. Adhesives85, 202–207 (2018)..
Kim, J. H., Hwang, J. H.&Lim, T. Y. A layer-by-layer self-assembly method for organic-inorganic hybrid multilayer thin films.J. Ceram. Process. Res.10, 770–773 (2009)..
Daimon, M.&Masumura, A. Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region.Appl. Opt.46, 3811–3820 (2007)..
McMeekin, T. L., Groves, M. L.&Hipp, N. J. Refractive indices of amino acids, proteins, and related substances. InAmino Acids and Serum Proteins(ed. Stekol, J. A.) 54–66 (Washington: American Chemical Society, 1964).
Halwer, M., Nutting, G. C.&Brice, B. A. Molecular weight of lactoglobulin, ovalbumin, lysozyme and serum albumin by light scattering.J. Am. Chem. Soc.73, 2786–2790 (1951)..
Edelhoch, H. The properties of thyroglobulin. I. The effects of alkali.J. Biol. Chem.235, 1326–1334 (1960)..
Perlmann, G. E.&Longsworth, L. G. The specific refractive increment of some purified proteins.J. Am. Chem. Soc.70, 2719–2724 (1948)..
Barer, R.&Tkaczyk, S. Refractive index of concentrated protein solutions.Nature173, 821–822 (1954)..
Huglin, M. B. Specific refractive indexincrements of polymer solutions. Part Ⅰ. Literature values.J. Appl. Polym. Sci.9, 3963–4001 (1965)..
Tumolo, T., Angnes, L.&Baptista, M. S. Determination of the refractive index increment (dn/dc) of molecule and macromolecule solutions by surface plasmon resonance.Anal. Biochem.333, 273–279 (2004)..
Wright, A. K.&Thompson, M. R. Hydrodynamic structure of bovine serum albumin determined by transient electric birefringence.Biophys. J.15, 137–141 (1975)..
Peters, Jr. T. J. The Albumin molecule: its structure and chemical properties. InAll About Albumin. Biochemistry, Genetics, and Medical Applications, 9–75 (Academic Press, San Diego, 1996).
Levy, O.&Stroud, D. Maxwell Garnett theory for mixtures of anisotropic inclusions: application to conducting polymers.Phys. Rev. B56, 8035–8046 (1997)..
Sihvola, A.Electromagnetic Mixing Formulas and Applications(Institute of Electrical Engineers, London, 1999).
Sigma-Aldrich.A2153—Bovine Serum Albumin(Sigma-Aldrich, 2020).https://www.sigmaaldrich.com/catalog/product/sigma/a2153?lang=en&region=RUhttps://www.sigmaaldrich.com/catalog/product/sigma/a2153?lang=en&region=RU..
Agat-Med. Bilirubin Etalon Agat. (Agat-Med, 2020).https://www.agat.ru/documents/instructions/5075/https://www.agat.ru/documents/instructions/5075/.
Barozzi, M. et al. Optical fiber sensors for label-free DNA detection.J. Lightwave Technol.35, 3461–3472 (2017)..
Dinish, U. S. et al. Sensitive multiplex detection of serological liver cancer biomarkers using SERS-active photonic crystal fiber probe.J. Biophotonics7, 956–965 (2014)..
Dinish, U. S. et al. Highly sensitive SERS detection of cancer proteins in low sample volume using hollow core photonic crystal fiber.Biosens. Bioelectron.33, 293–298 (2012)..
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621