
1.Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20/4 L, 1090 Vienna, Austria
2.Research Centre for Microtechnology, Vorarlberg University of Applied Sciences, Hochschulstrasse 1, 6850 Dornbirn, Austria
3.AIT Austrian Institute of Technology GmbH, Gieffinggasse 4, 1210 Vienna, Austria
4.ams AG, Tobelbader Strasse 30, 8141 Premstaetten, Austria
Elisabet A. Rank (elisabet.rank@meduniwien.ac.at)
Published:2021,
Published Online:05 January 2021,
Received:27 March 2020,
Revised:14 November 2020,
Accepted:03 December 2020
Scan QR Code
Rank, E. A. et al. Toward optical coherence tomography on a chip: in vivo three-dimensional human retinal imaging using photonic integrated circuit-based arrayed waveguide gratings. Light: Science & Applications, 10, 71-85 (2021).
Rank, E. A. et al. Toward optical coherence tomography on a chip: in vivo three-dimensional human retinal imaging using photonic integrated circuit-based arrayed waveguide gratings. Light: Science & Applications, 10, 71-85 (2021). DOI: 10.1038/s41377-020-00450-0.
In this work
we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256
channels were tested
which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm
with which a sensitivity of up to 91 dB (830 µW
)
and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm
with which a sensitivity of 90 dB (480 µW
)
and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process
which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography
tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.
Drexler, W.&Fujimoto, J. G.Optical Coherence Tomography-Technology and Applications. (Cham: Springer International Publishing, 2015).
Swanson, E. A.&Fujimoto, J. G. The ecosystem that powered the translation of OCT from fundamental research to clinical and commercial impact.Biomed. Opt. Express8, 1638-1664 (2017)..
Wojtkowski, M. et al. In vivo human retinal imaging by Fourier domain optical coherence tomography.J. Biomed. Opt.7, 457-463 (2002)..
De Boer, J. F. , Leitgeb, R.&Wojtkowski, M. Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited].Biomed. Opt. Express8, 3248-3280 (2017)..
Chopra, R.&Keane, P. Optical coherence tomography-reinventing the eye examination.Eye News23, 3 (2016)..
McNamara, P. M. et al. Development of a first-generation miniature multiple reference optical coherence tomography imaging device.J. Biomed. Opt.21, 126020 (2016)..
Song, G. et al. First clinical application of low-cost OCT.Transl. Vis. Sci. Technol.8, 61 (2019)..
Kim, S. et al. Design and implementation of a low-cost, portable OCT system.Biomed. Opt. Express9, 1232-1243 (2018)..
Yang, J. L. et al. Handheld optical coherence tomography angiography.Biomed. Opt. Express8, 2287-2300 (2017)..
Lu, C. D. et al. Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.Biomed. Opt. Express5, 293-311 (2014)..
LaRocca, F. et al. Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system.Biomed. Opt. Express4, 2307-2321 (2013)..
Hainberger, R. et al. Silicon-nitride waveguide-based integrated photonic circuits for medical diagnostic and other sensing applications. inProc. SPIE, Smart Photonic and Optoelectronic Integrated Circuits XXI(SPIE, San Francisco, 2019).
Rahim, A. et al. Expanding the silicon photonics portfolio with silicon nitride photonic integrated circuits.J. Lightwave Technol.35, 639-649 (2017)..
Yurtsever, G. et al. Integrated photonic circuit in silicon on insulator for Fourier domain optical coherence tomography. inProc. SPIE, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XIV. (SPIE, San Francisco, 2010).
Yurtsever, G., Komorowska, K.&Baets, R. Low dispersion integrated Michelson interferometer on silicon on insulator for optical coherence tomography. inProc. SPIE, Optical Coherence Tomography and Coherence Techniques V. (SPIE, Munich, 2011).
Nguyen, V. D. et al. Integrated-optics-based swept-source optical coherence tomography.Opt. Lett.37, 4820-4822 (2012)..
Van Leeuwen, T. G. et al. On-chip Mach-zehnder interferometer for OCT systems.Adv. Opt. Technol.7, 103-106 (2018)..
Schneider, S. et al. Optical coherence tomography system mass-producible on a silicon photonic chip.Opt. Express24, 1573-1586 (2016)..
Wang, Z. et al. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection.Biomed. Opt. Express6, 2562-2574 (2015)..
Huang, Y. Y. et al. Wide-field high-speed space-division multiplexing optical coherence tomography using an integrated photonic device.Biomed. Opt. Express8, 3856-3867 (2017)..
Eggleston, M. S. et al. 90 dB sensitivity in a chip-scale swept-source optical coherence tomography system.Conference on Lasers and Electro-Optics. (Optical Society of America, San Jose, 2018).
Sancho-Durá, J. et al. Handheld multi-modal imaging for point-of-care skin diagnosis based on akinetic integrated optics optical coherence tomography.J. Biophotonics11, e201800193 (2018)..
Smit, M. K. New focusing and dispersive planar component based on an optical phased array.Electron. Lett.24, 385-386 (1988)..
Nguyen, V. D. et al. Spectral domain optical coherence tomography imaging with an integrated optics spectrometer.Opt. Lett.36, 1293-1295 (2011)..
Akca, B. I. et al. Toward spectral-domain optical coherence tomography on a chip.IEEE J. Sel. Top. Quantum Electron.18, 1223-1233 (2012)..
Akca, B. I. et al. Miniature spectrometer and beam splitter for an optical coherence tomography on a silicon chip.Opt. Express21, 16648-16656 (2013)..
Ruis, R. M. et al. Decreasing the size of a spectral domain optical coherence tomography system with cascaded arrayed waveguide gratings in a photonic integrated circuit.IEEE J. Sel. Top. Quantum Electron.25, 6100109 (2019)..
Ollion, J. et al. TANGO: a generic tool for high-throughput 3D image analysis for studying nuclear organization.Bioinformatics29, 1840-1841 (2013)..
Leitgeb, R. , Hitzenberger, C. K.&Fercher, A. F. Performance of fourier domain vs.time domain optical coherence tomography.Opt. Express11, 889-894 (2003)..
Hitzenberger, C. K. Optical measurement of the axial eye length by laser Doppler interferometry.Investig. Ophthalmol. Vis. Sci.32, 616-624 (1991)..
Chan, A. N. et al. Normal macular thickness measurements in healthy eyes using stratus optical coherence tomography.Arch. Ophthalmol.124, 193-198 (2006)..
Takada, N. et al. OCT-Based quantification and classification of optic disc structure in glaucoma patients.PLoS ONE11, e0160226 (2016)..
Kashani, A. H. et al. Optical coherence tomography angiography: a comprehensive review of current methods and clinical applications.Prog. Retinal Eye Res.60, 66-100 (2017)..
Camino, A. et al. Evaluation of artifact reduction in optical coherence tomography angiography with real-time tracking and motion correction technology.Biomed. Opt. Express7, 3905-3915 (2016)..
Spaide, R. F. , Koizumi, H.&Pozonni, M. C. Enhanced depth imaging spectral-domain optical coherence tomography.Am. J. Ophthalmol.146, 496-500 (2008)..
Singh, S. R. et al. Unique optical coherence tomographic features in age-related macular degeneration.Surv. Ophthalmol.https://doi.org/10.1016/j.survophthal.2020.01.001https://doi.org/10.1016/j.survophthal.2020.01.001(2020)..
Vlaskovic, M. et al. PIN-photodiode based active pixel in 0.35 μm high-voltage CMOS for optical coherence tomography. inProc. 2019 42nd International Convention on Information and Communication Technology, Electronics and Microelectronics. (IEEE, Opatija, 2019).
Haindl, R. et al. Ultra-high-resolution SD-OCM imaging with a compact polarization-aligned 840 nm broadband combined-SLED source.Biomed. Opt. Express11, 3395-3406 (2020)..
Seyringer, D.Arrayed Waveguide Gratings. (Bellingham: SPIE Press, 2016).
Seyringer, D. et al. Design and optimization of high-channel Si3N4 based AWGs for medical applications. in Proc. 6th International Conference on Photonics, Optics and Laser Technology. (SCITEPRESS—Science and Technology Publications, 2018).
Seyringer, D. et al. Technological verification of size-optimized 160-channel silicon nitride-based AWG-spectrometer for medical applications.Appl. Phys. B125, 88 (2019)..
Sagmeister, M. et al. Monolithically integrated, CMOS-compatible SiN photonics for sensing applications.Proceedings2, 1023 (2018)..
Seyringer, D. et al. Compact and high-resolution 256-channel silicon nitride based AWG-spectrometer for OCT on a chip. inProc. 2019 21st International Conference on Transparent Optical Networks. (IEEE, Angers, 2019).
Dorrer, C. et al. Spectral resolution and sampling issues in Fourier-transform spectral interferometry.J. Opt. Soc. Am. B17, 1795-1802 (2000)..
Wu, T. et al. Spectral phase based k-domain interpolation for uniform sampling in swept-source optical coherence tomography.Opt. Express19, 18430-18439 (2011)..
Wojtkowski, M. et al. Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation.Opt. Express12, 2404-2422 (2004)..
Thevenaz, P. , Ruttimann, U. E.&Unser, M. A pyramid approach to subpixel registration based on intensity.IEEE Trans. Image Process.7, 27-41 (1998)..
Salas, M. et al. Compact akinetic swept source optical coherence tomography angiography at 1060 nm supporting a wide field of view and adaptive optics imaging modes of the posterior eye.Biomed. Opt. Express9, 1871-1892 (2018)..
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621