
1.CAS Key Laboratory of Quantum Information, University of Science and Technology of China, 230026 Hefei, China
2.CAS Center For Excellence in Quantum Information and Quantum Physics, University of Science and Technology of China, 230026 Hefei, Anhui, China
3.National Laboratory of Solid State Microstructures and College of Engineering and Applied Sciences, Nanjing University, Nanjing, China
4.Collaborative Innovation Center of Advanced Microstructures, Nanjing University, 210093 Nanjing, China
Geng Chen (chengeng@ustc.edu.cn)
ChuanFeng Li (cfli@ustc.edu.cn)
Published:30 June 2021,
Published Online:17 May 2021,
Received:26 November 2020,
Revised:15 April 2021,
Accepted:21 April 2021
Scan QR Code
Yin, P. et al. Improving the precision of optical metrology by detecting fewer photons with biased weak measurement. Light: Science & Applications, 10, 1070-1077 (2021).
Yin, P. et al. Improving the precision of optical metrology by detecting fewer photons with biased weak measurement. Light: Science & Applications, 10, 1070-1077 (2021). DOI: 10.1038/s41377-021-00543-4.
In optical metrological protocols to measure physical quantities
it is
in principle
always beneficial to increase photon number
n
to improve measurement precision. However
practical constraints prevent the arbitrary increase of n due to the imperfections of a practical detector
especially when the detector response is dominated by the saturation effect. In this work
we show that a modified weak measurement protocol
namely
biased weak measurement significantly improves the precision of optical metrology in the presence of saturation effect. This method detects an ultra-small fraction of photons while maintains a considerable amount of metrological information. The biased pre-coupling leads to an additional reduction of photons in the post-selection and generates an extinction point in the spectrum distribution
which is extremely sensitive to the estimated parameter and difficult to be saturated. Therefore
the Fisher information can be persistently enhanced by increasing the photon number. In our magnetic-sensing experiment
biased weak measurement achieves precision approximately one order of magnitude better than those of previously used methods. The proposed method can be applied in various optical measurement schemes to remarkably mitigate the detector saturation effect with low-cost apparatuses.
Helstrom, C. W.Quantum Detection and Estimation Theory(Academic, 1976).
Holevo, A. S.Probabilistic and Statistical Aspects of Quantum Theory(North-Holland, 1982).
Yuan, H. D.&Fung, C. H. F. Quantum parameter estimation with general dynamics.npj Quantum Inf.3, 14 (2017)..
Wineland, D. J. et al. Spin squeezing and reduced quantum noise in spectroscopy.Phys. Rev. A46, R6797 (1992)..
Caves, C. M. Quantum-mechanical noise in an interferometer.Phys. Rev. D23, 1693 (1981)..
Lee, H., Kok, P.&Dowling, J. P. A quantum Rosetta stone for interferometry.J. Mod. Opt.49, 2325–2338 (2002)..
Braunstein, S. L. Quantum limits on precision measurements of phase.Phys. Rev. Lett.69, 3598–3601 (1992)..
Giovannetti, V., Lloyd, S.&Maccone, L. Quantum-enhanced measurements: beating the standard quantum limit.Science306, 1330–1336 (2004)..
Tan, S. H. et al. Quantum illumination with Gaussian states.Phys. Rev. Lett.101, 253601 (2008)..
Pirandola, S. Quantum reading of a classical digital memory.Phys. Rev. Lett.106, 090504 (2011)..
Nair, R.&Yen, B. J. Optimal quantum states for image sensing in loss.Phys. Rev. Lett.107, 193602 (2011)..
Bollinger,J. J. et al. Optimal frequency measurements with maximally correlated states.Phys. Rev. A54, R4649 (1996)..
Walther, P. et al. De Broglie wavelength of a non-local four-photon state.Nature429, 158–161 (2004)..
Afek, I., Ambar, O.&Silberberg, Y. High-NOON states by mixing quantum and classical light.Science328, 879–881 (2010)..
Goda, K. et al. A quantum-enhanced prototype gravitational-wave detector.Nat. Phys.4, 472–476 (2008)..
Grangier, P. et al. Squeezed-light-enhanced polarization interferometer.Phys. Rev. Lett.59, 2153–2156 (1987)..
Xiao, M., Wu, L. A.&Kimble, H. J. Precision measurement beyond the shot-noise limit.Phys. Rev. Lett.59, 278–281 (1987)..
Treps, N. et al. A quantum laser pointer.Science301, 940–943 (2003)..
Giovannetti, V., Lloyd, S.&Maccone, L. Advances in quantum metrology.Nat. Photonics5, 222–229 (2011)..
Schnabel, R. Squeezed states of light and their applications in laser interferometers.Phys. Rep.684, 1–51 (2017)..
Aharonov, Y., Albert, D. Z.&Vaidman, L. How the result of a measurement of a component of the spin of a Spin-1/2 particle can turn out to be 100.Phys. Rev. Lett.60, 1351–1354 (1988)..
Aharonov, Y.&Vaidman, L. inTime in Quantum Mechanics(eds Muga, J. G., Mayato, R. S.&Egusquiza, I. L. ) 369–412 (Springer, 2002).
Hallaji, M. et al. Weak-value amplification of the nonlinear effect of a single photon.Nat. Phys.13, 540–544 (2017)..
Hosten, O.&Kwiat, P. Observation of the spin hall effect of light via weak measurements.Science319, 787–790 (2008)..
Dixon, P. B. et al. Ultrasensitive beam deflection measurement via interferometric weak value amplification.Phys. Rev. Lett.102, 173601 (2009)..
Brunner, N.&Simon, C. Measuring small longitudinal phase shifts: weak measurements or standard interferometry?Phys. Rev. Lett.105, 010405 (2010)..
Xu, X. Y. et al. Phase estimation with weak measurement using a white light source.Phys. Rev. Lett.111, 033604 (2013)..
Ferrie, C.&Combes, J. Weak value amplification is suboptimal for estimation and detection.Phys. Rev. Lett.112, 040406 (2014)..
Knee, G. C.&Gauger, E. M. When amplification with weak values fails to suppress technical noise.Phys. Rev. X4, 011032 (2014)..
Dressel, J. et al.Colloquium: understanding quantum weak values: basics and applications.Rev. Mod. Phys.86, 307–316 (2014)..
Zhang, L. J., Datta, A.&Walmsley, I. A. Precision metrology using weak measurements.Phys. Rev. Lett.114, 210801 (2015)..
Alves, G. B. et al. Weak-value amplification as an optimal metrological protocol.Phys. Rev. A91, 062107 (2015)..
Vaidman, L. Weak value controversy.Philos. Trans. R. Soc. A Math. Phys. Eng. Sci.375, 20160395 (2017)..
Xu, L. et al. Approaching quantum-limited metrology with imperfect detectors by using weak-value amplification.Phys. Rev. Lett.125, 080501 (2020)..
Harris, J., Boyd, R. W.&Lundeen, J. S. Weak value amplification can outperform conventional measurement in the presence of detector saturation.Phys. Rev. Lett.118, 070802 (2017)..
Zhang, Z. H. et al. Ultrasensitive biased weak measurement for longitudinal phase estimation.Phys. Rev. A94, 053843 (2016)..
Li, D. M. et al. Optical rotation based chirality detection of enantiomers via weak measurement in frequency domain.Appl. Phys. Lett.112, 213701 (2018)..
Li, D. M. et al. A chiral sensor based on weak measurement for the determination of Proline enantiomers in diverse measuring circumstances.Biosens. Bioelectron.110, 103–109 (2018)..
Jaynes, E. T. inProbability Theory: The Logic of Science(ed. Bretthorst, G. L. ) (Cambridge University Press, 2003).
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621