1.Aix-Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Marseille, France
2.Nanofabrication Laboratory, Department of Microtechnology and Nanoscience, MC2, Chalmers University of Technology, SE-412 96, Gothenburg, Sweden
3.Aix Marseille Univ, CNRS, Centrale Marseille, FSCM (FR1739), CP2M, 13397, Marseille, France
4.MAX Ⅳ Laboratory, Fotongatan 2, 225 94, Lund, Sweden
5.Present address: Diamond Light Source, Harwell Science and Innovation Campus, Fermi Ave, Didcot, OX11 0DE, UK
Virginie Chamard (virginie.chamard@fresnel.fr)
Published:30 April 2022,
Published Online:25 March 2022,
Received:03 September 2021,
Revised:05 January 2022,
Accepted:01 March 2022
Scan QR Code
Li, P. et al. 4th generation synchrotron source boosts crystalline imaging at the nanoscale. Light: Science & Applications, 11, 662-673 (2022).
Li, P. et al. 4th generation synchrotron source boosts crystalline imaging at the nanoscale. Light: Science & Applications, 11, 662-673 (2022). DOI: 10.1038/s41377-022-00758-z.
New 4
th
-generation synchrotron sources
with their increased bril
liance
promise to greatly improve the performances of coherent X-ray microscopy. This perspective is of major interest for crystal microscopy
which aims at revealing the 3D crystalline structure of matter at the nanoscale
an approach strongly limited by the available coherent flux. Our results
based on Bragg ptychography experiments performed at the first 4
th
-generation synchrotron source
demonstrate the possibility of retrieving a high-quality image of the crystalline sample
with unprecedented quality. Importantly
the larger available coherent flux produces datasets with enough information to overcome experimental limitations
such as strongly deteriorated scanning conditions. We show this achievement would not be possible with 3
rd
-generation sources
a limit that has inhibited the development of this otherwise powerful microscopy method
so far. Hence
the advent of next-generation synchrotron sources not only makes Bragg ptychography suitable for high throughput studies but also strongly relaxes the associated experimental constraints
making it compatible with a wider range of experimental set-ups at the new synchrotrons.
Eriksson, M., van der Veen, J. F.&Quitmann, C. Diffraction-limited storage rings - a window to the science of tomorrow.J. Synchrotron Radiat.21, 837–842 (2014)..
Tavares, P. F. et al. Commissioning and first-year operational results of the MAX Ⅳ 3 GeV ring.J. Synchrotron Radiat.25, 1291–1316 (2018)..
Liu, L., Neuenschwander, R. T.&Rodrigues, A. R. D. Synchrotron radiation sources in Brazil.Philos. Trans. A Math. Phys. Eng. Sci.377, 20180235 (2019)..
Raimondi, P. ESRF-EBS: the extremely brilliant source project.Synchrotron Radiat. News29, 8–15 (2016)..
Björling, A. et al. Ptychographic characterization of a coherent nanofocused X-ray beam.Opt. Express28, 5069–5076 (2020)..
Kahnt, M. et al. Measurement of the coherent beam properties at the CoSAXS beamline.J. Synchrotron Radiat.28, 1948–1953 (2021)..
Stangl, J. et al.Nanobeam X-Ray Scattering: Probing Matter at the Nanoscale(Wiley-VCH, 2013).
Miao, J. W. et al. Beyond crystallography: diffractive imaging using coherent x-ray light sources.Science348, 530–535 (2015)..
Chapman, H. N.&Nugent, K. A. Coherent lensless X-ray imaging.Nat. Photonics4, 833–839 (2010)..
Pfeifer, M.A. et al. Three-dimensional mapping of a deformation field inside a nanocrystal.Nature442, 63–66 (2006)..
Ulvestad, A. et al. Topological defect dynamics in operando battery nanoparticles.Science348, 1344–1347 (2015)..
Singer, A. et al. Nucleation of dislocations and their dynamics in layered oxide cathode materials during battery charging.Nat. Energy3, 641–647 (2018)..
Clark, J. N. et al. Three-dimensional imaging of dislocation propagation during crystal growth and dissolution.Nat. Mater.14, 780–784 (2015)..
Dupraz, M. et al. 3D imaging of a dislocation loop at the onset of plasticity in an indented nanocrystal.Nano Lett.17, 6696–6701 (2017)..
Minkevich, A. A. et al. Inversion of the diffraction pattern from an inhomogeneously strained crystal using an iterative algorithm.Phys. Rev. B76, 104106 (2007)..
Godard, P. et al. Three-dimensional high-resolution quantitative microscopy of extended crystals.Nat. Commun.2, 568 (2011)..
Hruszkewycz, S. O. et al. Imaging local polarization in ferroelectric thin films by coherent X-ray Bragg projection ptychography.Phys. Rev. Lett.110, 177601 (2013)..
Takahashi, Y. et al. Bragg X-ray ptychography of a silicon crystal: visualization of the dislocation strain field and the production of a vortex beam.Phys. Rev. B87, 121201 (2013)..
Mastropietro, F. et al. Revealing crystalline domains in a mollusc shell single-crystalline prism.Nat. Mater.16, 946–952 (2017)..
Hruszkewycz, S. O. et al. High-resolution three-dimensional structural microscopy by single-angle Bragg ptychography.Nat. Mater.16, 244–251 (2017)..
Dzhigaev, D. et al. X-ray Bragg ptychography on a single InGaN/GaN core–shell nanowire.ACS Nano11, 6605–6611 (2017)..
Kim, C. et al. Three-dimensional imaging of phase ordering in an Fe-Al alloy by bragg ptychography.Phys. Rev. Lett.121, 256101 (2018)..
Hill, M. O. et al. Measuring three-dimensional strain and structural defects in a single InGaAs nanowire using coherent X-ray multiangle Bragg projection ptychography.Nano Lett.18, 811–819 (2018)..
Faulkner, H. M. L.&Rodenburg, J. M. Movable aperture lensless transmission microscopy: a novel phase retrieval algorithm.Phys. Rev. Lett.93, 023903 (2004)..
Thibault, P. et al. High-resolution scanning x-ray diffraction microscopy.Science321, 379–382 (2008)..
Dierolf, M. et al. Ptychographic X-ray computed tomography at the nanoscale.Nature467, 436–439 (2010)..
Pateras, A. I. et al. Nondestructive three-dimensional imaging of crystal strain and rotations in an extended bonded semiconductor heterostructure.Phys. Rev. B92, 205305 (2015)..
Li, P. et al. Revealing nano-scale lattice distortions in implanted material with 3D Bragg ptychography.Nat. Commun.12, 7059 (2021)..
Maiden, A. M. et al. An annealing algorithm to correct positioning errors in ptychography.Ultramicroscopy120, 64–72 (2012)..
Chamard, V. et al. Strain in a silicon-on-insulator nanostructure revealed by 3D X-ray Bragg ptychography.Sci. Rep.5, 9827 (2015)..
Thibault, P. et al. Probe retrieval in ptychographic coherent diffractive imaging.Ultramicroscopy109, 338–343 (2009)..
Maiden, A. M.&Rodenburg, J. M. An improved ptychographical phase retrieval algorithm for diffractive imaging.Ultramicroscopy109, 1256–1262 (2009)..
Thibault, P.&Menzel, A. Reconstructing state mixtures from diffraction measurements.Nature494, 68–71 (2013)..
Odstrčil, M., Menzel, A.&Guizar-Sicairos, M. Iterative least-squares solver for generalized maximum-likelihood ptychography.Opt. Express26, 3108–3123 (2018)..
Deng, J. J. et al. Continuous motion scan ptychography: characterization for increased speed in coherent x-ray imaging.Opt. Express23, 5438–5451 (2015)..
Huang, X. J. et al. Fly-scan ptychography.Sci. Rep.5, 9074 (2015)..
Pelz, P. M. et al. On-the-fly scans for X-ray ptychography.Appl. Phys. Lett.105, 251101 (2014)..
Li, P. et al. General approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part Ⅱ.J. Appl. Crystallogr.53, 404–418 (2020)..
Hansen, P. C. Analysis of discrete Ill-posed problems by means of the L-curve.SIAM Rev.34, 561–580 (1992)..
Woodward, P. M.Probability and Information Theory with Applications to Radar(Pergamon Press, 1953).
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621