Multi-energy X-ray detection is sought after for a wide range of applications including medical imaging
security checking and industrial flaw inspection. Perovskite X-ray detectors are superior in terms of high sensitivity and low detection limit
which lays a foundation for multi-energy discrimination. However
the extended capability of the perovskite detector for multi-energy X-ray detection is challenging and has never been reported. Herein we report the design of vertical matrix perovskite X-ray detectors for multi-energy detection
based on the attenuation behavior of X-ray within the detector and machine learning algorithm. This platform is independent of the complex X-ray source components that constrain the energy discrimination capability. We show that the incident X-ray spectra could be accurately reconstructed from the conversion matrix and measured photocurrent response. Moreover
the detector could produce a set of images containing the density-graded information under single exposure
and locate the concealed position for all low-
medium- and high-density substances. Our findings suggest a new generation of X-ray detectors with features of multi-energy discrimination
density differentiation
and contrast-enhanced imaging.
Spahn, M. X-ray detectors in medical imaging.Nucl. Instrum. Methods Phys. Res. Sect. A: Accelerators, Spectrometers, Detect. Associated Equip.731, 57–63 (2013)..
van Eijk, C. W. E. Inorganic scintillators in medical imaging.Phys. Med. Biol.47, R85–R106 (2002)..
Duan, X. H. et al. X-ray cargo container inspection system with few-view projection imaging.Nucl. Instrum. Methods Phys. Res. Sect. A: Accelerators, Spectrometers, Detect. Associated Equip.598, 439–444 (2009)..
Haff, R. P.&Toyofuku, N. X-ray detection of defects and contaminants in the food industry.Sens. Instrum. Food Qual. Saf.2, 262–273 (2008)..
Neutze, R. et al. Potential for biomolecular imaging with femtosecond X-ray pulses.Nature406, 752–757 (2000)..
Mazess, R. B. et al. Dual-energy x-ray absorptiometry for total-body and regional bone-mineral and soft-tissue composition.Am. J. Clin. Nutr.51, 1106–1112 (1990)..
Rebuffel, V.&Dinten, J. M. Dual-energy X-ray imaging: benefits and limits.Insight - Non-Destructive Test. Cond. Monit.49, 589–594 (2007)..
Ramos, R. M. L. et al. Dual energy X-ray absorptimetry: fundamentals, methodology, and clinical applications.Radiología54, 410–423 (2012)..
Ishigaki, T., Sakuma, S.&Ikeda, M. One-shot dual-energy subtraction chest imaging with computed radiography: clinical evaluation of film images.Radiology168, 67–72 (1988)..
Ishigaki, T. et al. One-shot dual-energy subtraction imaging.Radiology161, 271–273 (1986)..
Goo, H. W.&Goo, J. M. Dual-energy CT: new horizon in medical imaging.Korean J. Radiol.18, 555–569 (2017)..
Pietrobelli, A. et al. Dual-energy X-ray absorptiometry body composition model: review of physical concepts.Am. J. Physiol. -Endocrinol. Metab.271, E941–E951 (1996)..
Rowlands, J. A. Material change for X-ray detectors.Nature550, 47–48 (2017)..
Zhao, J. J. et al. Perovskite-filled membranes for flexible and large-area direct-conversion X-ray detector arrays.Nat. Photon.14, 612–617 (2020)..
Deumel, S. et al. High-sensitivity high-resolution X-ray imaging with soft-sintered metal halide perovskites.Nat. Electron.4, 681–688 (2021)..
Zhou, Y. et al. Heterojunction structures for reduced noise in large-area and sensitive perovskite x-ray detectors.Sci. Adv.7, eabg6716 (2021)..
Wei, H. T.&Huang, J. S. Halide lead perovskites for ionizing radiation detection.Nat. Commun.10, 1066 (2019)..
Zhuang, R. Z. et al. Highly sensitive X-ray detector made of layered perovskite-like (NH4)3Bi2I9single crystal with anisotropic response.Nat. Photon.13, 602–608 (2019)..
Maire, E. et al. On the application of X-ray microtomography in the field of materials science.Adv. Eng. Mater.3, 539–546 (2001)..
Berger, M. J. et al. XCOM: photon cross sections database. Gaithersburg, MD: National Institute of Standards and Technology. athttp://www.nist.gov/pml/data/xcom/index.cfmhttp://www.nist.gov/pml/data/xcom/index.cfm.
Xu, J. X. et al. Perovskite–fullerene hybrid materials suppress hysteresis in planar diodes.Nat. Commun.6, 7081 (2015)..
Tsai, H. et al. A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes.Sci. Adv.6, eaay0815 (2020)..
Ciavatti, A.et al. Boosting direct X-ray detection in organic thin films by small molecules tailoring.Adv. Funct. Mater.29, 1806119 (2019)..
Yakunin, S. et al. Detection of X-ray photons by solution-processed lead halide perovskites.Nat. Photon.9, 444–449 (2015)..
Koch, H. W.&Motz, J. W. Bremsstrahlung cross-section formulas and related data.Rev. Mod. Phys.31, 920–955 (1959)..
Kozorezov, A. G. et al. The effect of carrier diffusion on the characteristics of semiconductor imaging arrays.Nucl. Instrum. Methods Phys. Res. Sect. A: Accelerators Spectrometers Detect. Associated Equip.531, 52–55 (2004)..
del Risco Norrlid, L. et al. Calculation of the modulation transfer function for the X-ray imaging detector DIXI using Monte Carlo simulation data.Nucl. Instrum. Methods Phys. Res. Sect. A: Accelerators Spectrometers Detect. Associated Equip.466, 209–217 (2001)..
Kasap, S. et al. Amorphous and polycrystalline photoconductors for direct conversion flat panel X-ray image sensors.Sensors11, 5112–5157 (2011)..
Lohman, T. G.Advances in Body Composition Assessment, 1-23 (Champaign: Human Kinetics Publishers, 1992).
Ageyama, N. et al. Specific gravity of whole blood in cynomolgus monkeys (Macaca fascicularis), squirrel monkeys (Saimiri sciureus), and tamarins (Saguinus labiatus) and total blood volume in cynomolgus monkeys.J. Am. Assoc. Lab. Anim. Sci.40, 33–35 (2001)..
Fidanza, F. Body fat in adult man: semicentenary of fat density and skinfolds.Acta Diabetol.40, s242–s245 (2003)..
Salvat, F. et al. Monte Carlo simulation of bremsstrahlung emission by electrons.Radiat. Phys. Chem.75, 1201–1219 (2006)..
0
Views
0
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621