1.The Institute of Optics, University of Rochester, Rochester, NY 14627, USA
2.Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 130033 Changchun, China
Chunlei Guo (guo@optics.rochester.edu)
纸质出版日期:2018,
网络出版日期:2018-07-11,
收稿日期:2017-11-14,
修回日期:2018-04-17,
录用日期:2018-04-22
Scan QR Code
Complete characterization of ultrashort optical pulses with a phase-shifting wedged reversal shearing interferometer[J]. LSA, 2018,7(4):270-280.
Lam, B. & Guo, C. L. Complete characterization of ultrashort optical pulses with a phase-shifting wedged reversal shearing interferometer. Light: Science & Applications, 7, 270-280 (2018).
Complete characterization of ultrashort optical pulses with a phase-shifting wedged reversal shearing interferometer[J]. LSA, 2018,7(4):270-280. DOI: 10.1038/s41377-018-0022-0.
Lam, B. & Guo, C. L. Complete characterization of ultrashort optical pulses with a phase-shifting wedged reversal shearing interferometer. Light: Science & Applications, 7, 270-280 (2018). DOI: 10.1038/s41377-018-0022-0.
The ability of an interferometer to characterize the spatial information of a light beam is often limited by the temporal profile of the beam
with femtosecond pulse characterization being particularly challenging. In this study
we developed a simple
stable
controllable shearing and vectorial phase-shifting wedged reversal shearing interferometer that is able to characterize all types of coherent and partially coherent light beams. The proposed interferometer consists of only a single beam splitter cube with one wedged entrance face and is insensitive to environmental vibration due to its common path configuration. A near zero-path length difference of the proposed interferometer ensures its operation for ultrashort pulses
providing
for the first time
a simple and stable interferometric tool to fully characterize sub-100 fs laser pulses. All common beam characterization can be carried out with the interferometer
such as the amplitude
phase
polarization
wavelength
and pulse duration. Furthermore
this technique is sensitive to the wavefront tilt and can be used for precise beam alignment. Therefore
this interferometer can be an essential tool for beam characterization
optical imaging
and the testing required for a wide range of applications
including astronomy
biomedicine
ophthalmology
optical testing and imaging systems
and adaptive optics.
Brown, D. S. The application of shearing interferometry to routine optical testing.J. Sci. Instrum.32, 137–139 (1955)..
Malacara, D.Optical Shop Testing(John Wiley&Sons, New York, 2007).
Roddier, F.Adaptive Optics in Astronomy(Cambridge University Press, Cambridge, 1999).
Roorda, A. et al. Adaptive optics scanning laser ophthalmoscopy.Opt. Express10, 405–412 (2002)..
Riley, M. E.&Gusinow, M. A. Laser beam divergence utilizing a lateral shearing interferometer.Appl. Opt.16, 2753–2756 (1977)..
Soong, H. K.&Malta, J. B. Femtosecond lasers in ophthalmology.Am. J. Ophthalmol.147, 189–197 (2009). e2..
Juhasz, T. et al. Corneal refractive surgery with femtosecond lasers.IEEE J. Sel. Top. Quantum Electron.5, 902–910 (1999)..
Ding, L., Knox, W. H., Bühren, J., Nagy, L. J.&Huxlin, K. R. Intratissue refractive index shaping (IRIS) of the cornea and lens using a low-pulse-energy femtosecond laser oscillator.Invest Ophthalmol. Vis. Sci.49, 5332–5339 (2008)..
Murty, M. V. A compact lateral shearing interferometer based on the Michelson interferometer.Appl. Opt.9, 1146–1148 (1970)..
Paez, G., Strojnik, M.&Torales, G. G. Vectorial shearing interferometer.Appl. Opt.39, 5172–5178 (2000)..
Siebert, T.&Schmitz, B. New shearing setup for simultaneous measurement of two shear directions.Proc. SPIE3637, 225–230 (1999)..
Henning, T. D.&Carlsten, J. L. Cyclic shearing interferometer for collimating short coherence-length laser beams.Appl. Opt.31, 1199–1209 (1992)..
Gates, J. W. Reverse-shearing interferometry.Nature176, 359–360 (1955)..
Gates, J. W. The measurement of comatic aberrations by interferometry.Proc. Phys. Soc.68, 1065–1072 (1955)..
Sickinger, H., Falkenstoerfer, O., Lindlein, N.&Schwider, J. Characterization of microlenses using a phase-shifting shearing interferometer.Opt. Eng.33, 2680–2686 (1994)..
Song, J. B., Lee, Y. W., Lee, I. W.&Lee, Y. H. Simple phase-shifting method in a wedge-plate lateral-shearing interferometer.Appl. Opt.43, 3989–3992 (2004)..
Farrell, C. T.&Player, M. S. Phase step measurement and variable step algorithms in phase-shifting interferometry.Meas. Sci. Technol.3, 953–958 (1992)..
Deck, L. L. Fourier-transform phase-shifting interferometry.Appl. Opt.42, 2354–2365 (2003)..
Kinnstaetter, K., Lohmann, A. W., Schwider, J.&Streibl, N. Accuracy of phase shifting interferometry.Appl. Opt.27, 5082–5089 (1988)..
Ai, C.&Wyant, J. C. Effect of piezoelectric transducer nonlinearity on phase shift interferometry.Appl. Opt.26, 1112–1116 (1987)..
Cohen, L. The generalization of the Wiener-Khinchin theorem. InProc. 1998 IEEE International Conference on Acoustics, Speech and Signal Processing3, 1577–1580 (IEEE, Seattle, 1998)..
Trebino, R.&Kane, D. J. Using phase retrieval to measure the intensity and phase of ultrashort pulses: frequency-resolved optical gating.J. Opt. Soc. Am. A10, 1101–1111 (1993)..
Beckley, A. M., Brown, T. G.&Alonso, M. A. Full poincaré beams.Opt. Express18, 10777–10785 (2010)..
Darlin, J. S., Sriram, K. V., Kothiyal, M. P.&Sirohi, R. S. Modified double-wedge-plate shearing interferometer for collimation testing.Appl. Opt.34, 2886–2887 (1995)..
Sirohi, R. S.&Kothiyal, M. P. Double wedge plate shearing interferometer for collimation test.Appl. Opt.26, 4054–4056 (1987)..
Heintzmann, R. inFluorescence Microscopy: From Principles to Biological Applications2nd edn (ed. Kubitscheck, U.) 463–471 (John Wiley&Sons, New York, 2017).
Goldstein, D. H.Polarized Light3rd edn (CRC Press, Boca Raton, 2016).
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621