1.Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, 1200 East California Boulevard, Pasadena, CA 91125, USA
2.Department of Biomedical Engineering, Washington University in St. Louis, Campus Box 1097, One Brookings Drive, St. Louis, MO 63130-4899, USA
3.Present address: Translational and Advanced Bioimaging Laboratory, Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Hong Kong, China
Lihong V. Wang (LVW@caltech.edu)
纸质出版日期:2020,
网络出版日期:2020-07-31,
收稿日期:2020-03-01,
修回日期:2020-07-17,
录用日期:2020-07-20
Scan QR Code
Multifocal photoacoustic microscopy using a single-element ultrasonic transducer through an ergodic relay[J]. LSA, 2020,9(5):1299-1305.
Li, Y. et al. Multifocal photoacoustic microscopy using a single-element ultrasonic transducer through an ergodic relay. Light: Science & Applications, 9, 1299-1305 (2020).
Multifocal photoacoustic microscopy using a single-element ultrasonic transducer through an ergodic relay[J]. LSA, 2020,9(5):1299-1305. DOI: 10.1038/s41377-020-00372-x.
Li, Y. et al. Multifocal photoacoustic microscopy using a single-element ultrasonic transducer through an ergodic relay. Light: Science & Applications, 9, 1299-1305 (2020). DOI: 10.1038/s41377-020-00372-x.
Optical-resolution photoacoustic microscopy (OR-PAM) has demonstrated high-spatial-resolution imaging of optical absorption in biological tissue. To date
most OR-PAM systems rely on mechanical scanning with confocally aligned optical excitation and ultrasonic detection
limiting the wide-field imaging speed of these systems. Although several multifocal OR-PA (MFOR-PA) systems have attempted to address this limitation
they are hindered by the complex design in a constrained physical space. Here
we present a two-dimensional (2D) MFOR-PAM system that utilizes a 2D microlens array and an acoustic ergodic relay. Using a single-element ultrasonic transducer
this system can detect PA signals generated from 400 optical foci in parallel and then raster scan the optical foci patterns to form an MFOR-PAM image. This system improves the imaging resolution of an acoustic ergodic relay system from 220 to 13 μm and enables 400-folds shorter scanning time than that of a conventional OR-PAM system at the same resolution and laser repetition rate. We demonstrated the imaging ability of the system with both in vitro and in vivo experiments.
Yao, J. J., Song, L.&Wang, L. V. Photoacoustic microscopy: superdepth, superresolution, and superb contrast.IEEE Pulse6, 34–37 (2015)..
Hai, P. F. et al. Near-infrared optical-resolution photoacoustic microscopy.Opt. Lett.39, 5192–5195 (2014)..
Yao, J. J. et al. High-speed label-free functional photoacoustic microscopy of mouse brain in action.Nat. Methods12, 407–410 (2015)..
Wong, T. T. W. et al. Label-free automated three-dimensional imaging of whole organs by microtomy-assisted photoacoustic microscopy.Nat. Commun.8, 1386 (2017)..
Li, G., Maslov, K. I.&Wang, L. V. Reflection-mode multifocal optical-resolution photoacoustic microscopy.J. Biomed. Opt.18, 030501 (2013)..
Xia, J. et al. Wide-field two-dimensional multifocal optical-resolution photoacoustic-computed microscopy.Opt. Lett.38, 5236–5239 (2013)..
Draeger, C.&Fink, M. One-channel time reversal of elastic waves in a chaotic 2D-silicon cavity.Phys. Rev. Lett.79, 407–410 (1997)..
Ing, R. K. et al. In solid localization of finger impacts using acoustic time-reversal process.Appl. Phys. Lett.87, 204104 (2005)..
Montaldo, G. et al. Building three-dimensional images using a time-reversal chaotic cavity.IEEE Trans. Ultrason., Ferroelectr., Frequency Control52, 1489–1497 (2005)..
Cox, B. T.&Beard, P. C. Photoacoustic tomography with a single detector in a reverberant cavity.J. Acoustical Soc. Am.125, 1426–1436 (2009)..
Brown, M. D. et al. Reverberant cavity photoacoustic imaging.Optica6, 821–822 (2019)..
Li, Y. et al. Snapshot photoacoustic topography through an ergodic relay for high-throughput imaging of optical absorption.Nat. Photonics14, 164–170 (2020)..
Li, Y. et al. Photoacoustic topography through an ergodic relay for functional imaging and biometric applicationin vivo.J. Biomed. Opt.25, 070501 (2020)..
Prevedel, R. et al. Simultaneous whole-animal 3D imaging of neuronal activity using light-field microscopy.Nat. Methods11, 727–730 (2014)..
Fujita, K. et al. Confocal multipoint multiphoton excitation microscope with microlens and pinhole arrays.Opt. Commun.174, 7–12 (2000)..
Guggenheim, J. A. et al. Ultrasensitive plano-concave optical microresonators for ultrasound sensing.Nat. Photonics11, 714–721 (2017)..
Wong, T. T. W. et al. Fast label-free multilayered histology-like imaging of human breast cancer by photoacoustic microscopy.Sci. Adv.3, 1602168 (2017)..
Wang, L. V.&Hu, S. Photoacoustic tomography: in vivo imaging from organelles to organs.Science335, 1458–1462 (2012)..
Xia, J., Yao, J. J.&Wang, L. V. Photoacoustic tomography: principles and advances.Prog. Electromagnetics Res.147, 1–22 (2014)..
Bioucas-Dias, J. M.&Figueiredo, M. A. T. A new TwIST: two-step iterative shrinkage/thresholding algorithms for image restoration.IEEE Trans. Image Process.16, 2992–3004 (2007)..
Laser Institute of America.American National Standard for the safe use of lasers(American National Standards Institute, 2000).
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621