1.Department of Electrical and Electronic Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong, SAR 999077, China
2.Department of Physics, University of California, Berkeley, CA 94720, USA
3.School of Biomedical Sciences, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, SAR 999077, China
4.Department of Psychiatry, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, SAR 999077, China
5.GHM Institute of CNS Regeneration, Jinan University, 601 Huangpu Avenue West, Guangzhou 510632, China
6.Re-Stem Biotechnology, Suzhou 215007, China
Kevin K. Tsia (tsia@hku.hk)
纸质出版日期:2020,
网络出版日期:2020-01-20,
收稿日期:2019-05-31,
修回日期:2019-12-23,
录用日期:2020-01-06
Scan QR Code
Parallelized volumetric fluorescence microscopy with a reconfigurable coded incoherent light-sheet array[J]. LSA, 2020,9(1):71-81.
Ren, X. Y. et al. Parallelized volumetric fluorescence microscopy with a reconfigurable coded incoherent light-sheet array. Light: Science & Applications, 9, 71–81 (2020).
Parallelized volumetric fluorescence microscopy with a reconfigurable coded incoherent light-sheet array[J]. LSA, 2020,9(1):71-81. DOI: 10.1038/s41377-020-0245-8.
Ren, X. Y. et al. Parallelized volumetric fluorescence microscopy with a reconfigurable coded incoherent light-sheet array. Light: Science & Applications, 9, 71–81 (2020). DOI: 10.1038/s41377-020-0245-8.
Parallelized fluorescence imaging has been a long-standing pursuit that can address the unmet need for a comprehensive three-dimensional (3D) visualization of dynamical biological processes with minimal photodamage. However
the available approaches are limited to incomplete parallelization in only two dimensions or sparse sampling in three dimensions. We hereby develop a novel fluorescence imaging approach
called coded light-sheet array microscopy (CLAM)
which allows complete parallelized 3D imaging without mechanical scanning. Harnessing the concept of an "infinity mirror"
CLAM generates a light-sheet array with controllable sheet density and degree of coherence. Thus
CLAM circumvents the common complications of multiple coherent light-sheet generation in terms of dedicated wavefront engineering and mechanical dithering/scanning. Moreover
the encoding of multiplexed optical sections in CLAM allows the synchronous capture of all sectioned images within the imaged volume. We demonstrate the utility of CLAM in different imaging scenarios
including a light-scattering medium
an optically cleared tissue
and microparticles in fluidic flow. CLAM can maximize the signal-to-noise ratio and the spatial duty cycle
and also provides a further reduction in photobleaching compared to the major scanning-based 3D imaging systems. The flexible implementation of CLAM regarding both hardware and software ensures compatibility with any light-sheet imaging modality and could thus be instrumental in a multitude of areas in biological research.
Ji, N., Freeman, J.&Smith, S. L. Technologies for imaging neural activity in large volumes.Nat. Neurosci.19, 1154-1164 (2016)..
Weisenburger, S.&Vaziri, A. A guide to emerging technologies for large-scale and whole-brain optical imaging of neuronal activity.Annu. Rev. Neurosci.41, 431-452 (2018)..
Keller, P. J.&Ahrens, M. B. Visualizing whole-brain activity and development at the single-cell level using light-sheet microscopy.Neuron85, 462-483 (2015)..
Olarte, O. E., Andilla, J., Artigas, D.&Loza-Alvarez, P. Decoupled illumination detection in light sheet microscopy for fast volumetric imaging.Optica2, 702-705 (2015)..
Duocastella, M. et al. Fast inertia-free volumetric light-sheet microscope.ACS Photonics4, 1797-1804 (2017)..
Bouchard, M. B. et al. Swept confocally-aligned planar excitation (SCAPE) microscopy for high-speed volumetric imaging of behaving organisms.Nat. Photonics9, 113-119 (2015)..
Keller, P. J., Schmidt, A. D., Wittbrodt, J.&Stelzer, E. H. K. Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy.Science322, 1065-1069 (2008)..
Huisken, J.&Stainier, D. Y. R. Selective plane illumination microscopy techniques in developmental biology.Development136, 1963-1975 (2009)..
Cheng, A., Gonçalves, J. T., Golshani, P., Arisaka, K.&Portera-Cailliau, C. Simultaneous two-photon calcium imaging at different depths with spatiotemporal multiplexing.Nat. Methods8, 139-142 (2011)..
Geissbuehler, S. et al. Live-cell multiplane three-dimensional super-resolution optical fluctuation imaging.Nat. Commun.5, 5830 (2014)..
Abrahamsson, S. et al. Fast multicolor 3D imaging using aberration-corrected multifocus microscopy.Nat. Methods10, 60-63 (2013)..
Chen, B.-C. et al. Lattice light-sheet microscopy: Imaging molecules to embryos at high spatiotemporal resolution.Science346, 1257998 (2014)..
Mohan, K., Purnapatra, S. B.&Mondal, P. P. Three dimensional fluorescence imaging using multiple light-sheet microscopy.PLoS ONE9, e96551 (2014)..
Dean, K. M. et al. Imaging subcellular dynamics with fast and light-efficient volumetrically parallelized microscopy.Optica4, 263-271 (2017)..
Ma, Q. et al. Three-dimensional fluorescent microscopy via simultaneous illumination and detection at multiple planes.Sci. Rep.6, 31445 (2016)..
Mondal, P. P., Dilipkumar, S.&Mohan, K. Efficient generation of diffraction-limited multi-sheet pattern for biological imaging.Opt. Lett.40, 609-612 (2015)..
Dean, K. M.&Fiolka, R. Lossless Three-dimensional parallelization in digitally scanned light-sheet fluorescence microscopy.Sci. Rep.7, 9332 (2017)..
Badon, A. et al. Video-rate large-scale imaging with Multi-Z confocal microscopy.Optica6, 389-395 (2019)..
Judkewitz, B.&Yang, C. Axial standing-wave illumination frequency-domain imaging (SWIF).Opt. Express22, 11001-11010 (2014)..
Prevedel, R. et al. Simultaneous whole-animal 3D imaging of neuronal activity using light-field microscopy.Nat. Methods11, 727-730 (2014)..
Skocek, O. et al. High-speed volumetric imaging of neuronal activity in freely moving rodents.Nat. Methods15, 429-432 (2018)..
Cong, L. et al. Rapid whole brain imaging of neural activity in freely behaving larval zebrafish (Danio rerio).eLife6, e28158 (2017)..
Yan, W., Wu, J., Wong, K. K. Y.&Tsia, K. K. A high-throughput all-optical laser-scanning imaging flow cytometer with biomolecular specificity and subcellular resolution.J. Biophotonics11, e201700178 (2018)..
Wu, J.-L. et al. Ultrafast laser-scanning time-stretch imaging at visible wavelengths.Light.: Sci. Appl.6, e16196 (2017)..
Wu, J.-L. et al. Multi-MHz laser-scanning single-cell fluorescence microscopy by spatiotemporally encoded virtual source array.Biomed. Opt. Express8, 4160-4171 (2017)..
van Nee, R.&Prasad, R.OFDM for Wireless Multimedia Communications(Artech House, Norwood, MA, USA, 2000).
Mikami, H. et al. Ultrafast confocalfluorescence microscopy beyond the fluorescence lifetime limit.Optica5, 117-126 (2018)..
Diebold, E. D., Buckley, B. W., Gossett, D. R.&Jalali, B. Digitally synthesized beat frequency multiplexing for sub-millisecond fluorescence microscopy.Nat. Photonics7, 806-810 (2013)..
Howard, S. S., Straub, A., Horton, N. G., Kobat, D.&Xu, C. Frequency-multiplexed in vivo multiphoton phosphorescence lifetime microscopy.Nat. Photonics7, 33-37 (2013)..
Futia, G., Schlup, P., Winters, D. G.&Bartels, R. A. Spatially-chirped modulation imaging of absorption and fluorescent objects on single-element optical detector.Opt. Express19, 1626-1640 (2011)..
Higley, D. J., Winters, D. G.&Bartels, R. A. Two-dimensional spatial-frequency-modulated imaging through parallel acquisition of line images.Opt. Lett.38, 1763-1765 (2013)..
Tomer, R. et al. SPED light sheet microscopy: fast mapping of biological system structure and function.Cell163, 1796-1806 (2015)..
Piazza, S., Bianchini, P., Sheppard, C., Diaspro, A.&Duocastella, M. Enhanced volumetric imaging in 2‐photon microscopy via acoustic lens beam shaping.J. Biophotonics11, e201700050 (2018)..
Voleti, V. et al. Real-time volumetric microscopy of in vivo dynamics and large-scale samples with SCAPE 2.0.Nat. Methods16, 1054-1062 (2019)..
Jacques, S. L. Optical properties of biological tissues: a review.Phys. Med. Biol.58, R37-R61 (2013)..
Richardson, D. S.&Lichtman, J. W. Clarifying tissue clearing.Cell162, 246-257 (2015)..
Lai, H. M. et al. Next generation histology methods for three-dimensional imaging offresh and archival human brain tissues.Nat. Commun.9, 1066 (2018)..
Lai, H. M. et al. Rationalisation and validation of an acrylamide-free procedure in three-dimensional histological imaging.PLoS ONE11, e0158628 (2016)..
Li, Y. W. et al. Direct labeling and visualization of blood vessels with lipophilic carbocyanine dye DiI.Nat. Protoc.3, 1703-1708 (2008)..
Mubaid, F.&Brown, C. M. Less is more: longer exposure times with low light intensity is less photo-toxic.Microsc. Today25, 26-35 (2017)..
Tomer, R., Khairy, K., Amat, F.&Keller, P. J. Quantitative high-speed imaging of entire developing embryos with simultaneous multiview light-sheet microscopy.Nat. Methods9, 755-763 (2012)..
Fu, Q. Y. et al. Imaging multicellular specimens with real-time optimized tiling light-sheet selective plane illumination microscopy.Nat. Commun.7, 11088 (2016)..
Chang, B.-J. et al. Universal light-sheet generation with field synthesis.Nat. Methods16, 235-238 (2019)..
Gao, L., Tang, W.-C., Tsai, Y.-C.&Chen, B.-C. Lattice light sheet microscopy using tiling lattice light sheets.Opt. Express27, 1497-1506 (2019)..
Ji, N., Milkie, D. E.&Betzig, E. Adaptive optics via pupil segmentation for high-resolution imaging in biological tissues.Nat. Methods7, 141-147 (2010)..
Schneider, C. A., Rasband, W. S.&Eliceiri, K. W. NIH Image to ImageJ: 25 years of image analysis.Nat. Methods9, 671-675 (2012)..
Schindelin, J. et al. Fiji: an open-source platform for biological-image analysis.Nat. Methods9, 676-682 (2012)..
0
浏览量
0
Downloads
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621